Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This report describes technical tricks for using the reamer irrigator aspirator to harvest autologous bone graft from the femur. This device is a focus of interest in orthopaedics because it can be used to harvest bone graft from the femoral canal and medial condyle in voluminous quantities. Moreover, according to some authors, the osteogenic potential of this graft is at least as effective as that of autogenous bone obtained from the iliac crest. The reamer irrigator aspirator device has substantially different design characteristics and technicalities compared with those of a standard reamer. First, a guidewire must be redirected into multiple areas, including the center of the distal femur and into both condyles, to harvest ample bone graft. This is accomplished by prebending the guidewire in a stronger fashion than required for regular reaming in the case of femoral nailing procedures. This bend can increase the risk for eccentric reaming as well as lodging of the suctioning device within the femoral canal. Second, the front and lateral drilling surfaces of this device are very sharp and further cleaned and maintained sharp by the irrigation process to permit the surgeon to obtain significant volumes of graft with a single passage of this device. At the same time, however, this sharp front-end cutting design can increase the risk of iatrogenic fracture if reaming is performed without caution. Third, a powerful suctioning device is connected to the reamer such that the blood loss that can occur during continuous reaming, irrigation, and aspiration must be considered with this technique. We hereby discuss these potential dangers and describe the correct use of this device with technical tricks to minimize the risk of unexpected intraoperative events.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0b013e3181b2b4ebDOI Listing

Publication Analysis

Top Keywords

bone graft
16
technical tricks
12
reamer irrigator
12
irrigator aspirator
12
tricks reamer
8
autologous bone
8
femoral canal
8
increase risk
8
suctioning device
8
device
7

Similar Publications

NSG-SGM3 humanized mouse models are well-suited for studying human immune physiology but are technically challenging and expensive. We previously characterized a simplified NSG-SGM3 mouse, engrafted with human donor CD34 hematopoietic stem cells without receiving prior bone marrow ablation or human secondary lymphoid tissue implantation, that still retains human mast cell- and basophil-dependent passive anaphylaxis responses. Its capacities for human antibody production and human B cell maturation, however, remain unknown.

View Article and Find Full Text PDF

Purpose: Acute graft-versus-host disease (aGVHD) is a significant cause of death in recipients of allogeneic hematopoietic stem cell transplantation. In this type of graft, the intestine is particularly affected, with the loss of intestinal barrier integrity playing a key role in its onset. In this scenario, the aim of the present research was to evaluate defibrotide, a heparin-like compound, marked for severe veno-occlusive disease, as an innovative therapeutic approach for restoring intestinal barrier integrity using an in vitro model and analyzing aGVHD patients' sera and clinical data.

View Article and Find Full Text PDF

Introduction: The impact of race on outcomes of allogeneic hematopoietic cell transplants (HCT) has long been a field of research. The Center for International Blood and Marrow Transplant Research (CIBMTR) studies have shown worse survival for Black and Hispanic patients within the first year after HCT, but rates evened out for one-year survivors. From our personal experience, we hypothesize that the outcomes of South Asians (age ≥ 45 years) receiving myeloablative conditioning (MAC) are also worse compared to other races.

View Article and Find Full Text PDF

Case presentationDescription of a patient with a progressive destructive lung disease resembling pleuroparenchymal fibroelastosis, liver cirrhosis and bone marrow changes. Genetic workup identified a rare heterozygous coding variant in the (telomerase reverse transcriptase) gene c.472 C>T; p.

View Article and Find Full Text PDF