A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Real time PCR detection of the PI*Z and PI*S mutations associated with alpha-1 antitrypsin deficiency. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Alpha-1 antitrypsin (A1AT or AAT) is a serine protease inhibitor (PI) which, when present at low levels, can cause chronic obstructive pulmonary disease (COPD) and liver disease in both children and adults. Several mutations within the SERPINA1 gene have been found to cause this deficiency. The most common variants are PI*Z and PI*S, each caused by a single nucleotide polymorphism (SNP). We describe a real time polymerase chain reaction (PCR) assay for the rapid genotyping of these polymorphisms. DNA was extracted from fourteen EDTA-anticoagulated whole blood samples using the Qiagen EZ1 blood extraction kit. SNP genotyping was performed using primer/probe sets purchased from Applied Biosystems. These were evaluated for performance and assay conditions on the Applied Biosystems 7500 FAST System. The genotypes of these samples were compared with their phenotype results from isoelectric focusing assays, which were performed by an independent reference laboratory. In addition, twenty samples that were previously genotyped at another laboratory were obtained for accuracy studies. Thirty-four samples were tested; five genotypes were represented and the assay was able to discriminate these successfully. Only one genotype could not be correlated with its phenotype result, as the phenotype was reported as an "unidentified allele". All other genotyping results were concordant with previously determined genotypes and phenotypes. We describe a rapid real time PCR assay that is suitable for clinical use in genotyping AAT alleles and which can be used as the initial step in A1AT testing algorithms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2780033PMC

Publication Analysis

Top Keywords

real time
12
time pcr
8
pi*z pi*s
8
alpha-1 antitrypsin
8
pcr assay
8
applied biosystems
8
pcr detection
4
detection pi*z
4
pi*s mutations
4
mutations associated
4

Similar Publications