A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

In vitro analysis of patellar kinematics: validation of an opto-electronic cinematic analysis protocol. | LitMetric

In vitro analysis of patellar kinematics: validation of an opto-electronic cinematic analysis protocol.

Knee Surg Sports Traumatol Arthrosc

Laboratoire de Physiologie de l'Exercice, 4338, Saint Etienne, France.

Published: February 2010


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Opto-electronic cinematic analysis has already proven useful in the investigation of patients with a knee replacement; however, neither patellar tracking nor the various positional parameters relevant to instability such as patellar tilt and/or patellar shift have ever been specifically evaluated using this type of system. The aim of this research was to validate the relevance of this type of cinematic analysis in order to use it in the evaluation of the main factors underlying patellar instability. Six fresh-frozen anatomical specimens were studied. The data were acquired using the Motion Analysis system. Statistical analysis reveals a good reproducibility of measurements. Our protocol based on an opto-electronic acquisition system has an accuracy of 0.23 mm for shift and of 0.4 degrees for rotation, which is calculated by integrating the various experimental parameters and instrumental features specific to the Motion Analysis system. The results are consistent with published results which further attests to the validity and the efficacy of the protocol and encourages us that this protocol is suitable for the in vitro study of patellar kinematics.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-009-0956-0DOI Listing