A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: In the current study, we aimed to compare the diagnostic efficacies of phase-contrast magnetic resonance imaging (PC-MRI) and three-dimensional constructive interference in steady-state (3D-CISS) sequence over detection of aqueductal stenosis (AS) on the basis of contrast-enhanced magnetic resonance cisternography (MRC).

Methods: Twenty-five patients with clinically and radiologically suspected AS were examined by PC-MRI, 3D-CISS, and MRC. Axial-sagittal PC-MRI and sagittal 3D-CISS were applied to view the cerebral aqueduct. Following injection of 0.5-1 ml intrathecal gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) injection, postcontrast MRC images were obtained in three planes in early and late phases. Aqueductal patency was scored as follows: grade 0, normal; grade 1, partial narrowing; and grade 2, complete obstruction. Results of PC-MRI and 3D-CISS were compared with the findings of MRC.

Results: In PC-MRI, seven cases were assessed as grade 0, 16 cases grade 1, and two cases grade 2. As a result of 3D-CISS sequence, eight cases were evaluated as grade 0, 12 cases grade 1, and five cases grade 2. Based on MRC, nine cases were assessed as grade 0, whereas nine and seven cases were evaluated to be grades 1 and 2, respectively. Five cases that demonstrated partial patency in PC-MRI or 3D-CISS showed complete obstruction by MRC.

Conclusion: PC-MRI is helpful in confirming the AS. However, positive flow does not necessarily exclude the existence of AS. 3D-CISS sequence provides excellent cerebrospinal fluid-to-aqueduct contrast, allowing detailed study of the anatomic features of the aqueduct. MRC should be performed on patients who demonstrate suspected AS findings on PC-MRI and/or 3D-CISS sequences.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-009-0592-xDOI Listing

Publication Analysis

Top Keywords

grade cases
20
cases grade
16
3d-ciss sequence
12
pc-mri 3d-ciss
12
grade
10
3d-ciss
9
cases
9
aqueductal stenosis
8
magnetic resonance
8
pc-mri
8

Similar Publications