A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Modifications to the sunset laboratory carbon aerosol monitor for the simultaneous measurement of PM2.5 nonvolatile and semi-volatile carbonaceous material. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Semi-volatile organic carbonaceous material (SVOC) in fine particles is not reliably measured with conventional semicontinuous carbon monitors because semi-volatile carbonaceous material is lost from the collection media during sample collection. Two modifications of a Sunset Laboratory carbon aerosol monitor allowing for the determination of semi-volatile fine particulate organic material are described. Collocated conventional and modified instruments were operated simultaneously using a common inlet. Comparisons were made with integrated PC-BOSS data for quartz filter retained nonvolatile organic carbon (NVOC) and elemental carbon (EC), SVOC, and total carbon (TC = SVOC + NVOC + EC) and good agreement was observed between TC concentrations during studies conducted in Rubidoux, CA. Precision of the comparison was sigma = +/-1.5 microg-C/m3 (+/-8%). On the basis of experiments performed with the modified Sunset monitor, a dual-oven Sunset monitor was developed and extensively tested in Lindon, UT; Riverside, CA; and in environmental exposure chambers. The precision for the measurement of TC with the dual-oven instrument was sigma = +/-1.4 microg-C/m3 (+/-13%).

Download full-text PDF

Source
http://dx.doi.org/10.3155/1047-3289.59.8.1007DOI Listing

Publication Analysis

Top Keywords

carbonaceous material
12
modifications sunset
8
sunset laboratory
8
laboratory carbon
8
carbon aerosol
8
aerosol monitor
8
semi-volatile carbonaceous
8
carbon svoc
8
sunset monitor
8
carbon
6

Similar Publications