A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A modified rabbit model of stroke: evaluation using clinical MRI scanner. | LitMetric

A modified rabbit model of stroke: evaluation using clinical MRI scanner.

Neurol Res

Department of Medical Imaging, Second Hospital, Hebei Medical University, Shijiazhuang, Hebei Province, China.

Published: December 2009


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Occluding the middle cerebral artery of small animals with an intraluminal filament to build a stroke model has gained increasing acceptance. In light of the growing demand for magnetic resonance imaging (MRI) studies using the clinical MRI scanner, large animal models can be superior to small animal models. In this work, we developed a modified rabbit model of stroke, which was assessed using clinical MRI scanner and compared with a most commonly silicone-coated filament model.

Methods: We presented a focal cerebral ischemia in rabbits. The key feature of this modified method is the use of a guide wire as a 'nylon suture'. At 3 days after ischemia, the percentage of brain infarct volume, neurobehavioral score, intracranial hemorrhagic incidence and dynamic changes of T(2) and apparent diffusion coefficient values were assessed respectively and compared between the focal cerebral models.

Results: Wire-induced models had more severe brain infarct size with less dispersion (32.7 +/- 6.5%, coefficient of variation=0.20) than that with filament models (25.4 +/- 8.9%, coefficient of variation=0.31; p<0.05). There were more significant MRI changes in the early stage, higher rate of technique success (wire, 20/20; filament, 17/20) and less intracranial hemorrhage (wire, 0/20; filament, 3/20) in wire-induced models than in filament-induced rabbits (p<0.05).

Conclusion: Our data suggest that wire-induced method can provide a useful tool for the earlier research of ischemia.

Download full-text PDF

Source
http://dx.doi.org/10.1179/174313209X405100DOI Listing

Publication Analysis

Top Keywords

clinical mri
12
mri scanner
12
modified rabbit
8
rabbit model
8
model stroke
8
animal models
8
focal cerebral
8
brain infarct
8
stroke evaluation
4
evaluation clinical
4

Similar Publications