98%
921
2 minutes
20
The mechanomyographic (MMG) signal analysis has been performed during single motor unit (MU) contractions of the rat medial gastrocnemius muscle. The MMG has been recorded as a muscle surface displacement by using a laser distance sensor. The profiles of the MMG signal let to categorize these signals for particular MUs into three classes. Class MMG-P (positive) comprises MUs with the MMG signal similar to the force signal profile, where the distance between the muscle surface and the laser sensor increases with the force increase. The class MMG-N (negative) has also the MMG profile similar to the force profile, however the MMG is inverted in comparison to the force signal and the distance measured by using laser sensor decreases with the force increase. The third class MMG-M (mixed) characterize the MMG which initially increases with the force increases and when the force exceeds some level it starts to decrease towards the negative values. The semi-pennate muscle model has been proposed, enabling estimation of the MMG generated by a single MU depending on its localization. The analysis have shown that in the semi-pennate muscle the localization of the MU and the relative position of the laser distance sensor determine the MMG profile and amplitude. Thus, proposed classification of the MMG recordings is not related to the physiological types of MUs, but only to the MU localization and mentioned sensor position. When the distance sensor is located over the middle of the muscle belly, a part of the muscle fibers have endings near the location of the sensor beam. For the MU MMG of class MMG-N the deflection of the muscle surface proximal to the sensor mainly influences the MMG recording, whereas for the MU MMG class MMG-P, it is mainly the distal muscle surface deformation. For the MU MMG of MMG-M type the effects of deformation within the proximal and distal muscle surfaces overlap. The model has been verified with experimental recordings, and its responses are consistent and adequate in comparison to the experimental data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jelekin.2008.03.007 | DOI Listing |
Cureus
August 2025
School of Medicine, Universidad Central del Caribe, Bayamon, PRI.
Background Breast augmentation surgery (BAS) is one of the top cosmetic surgical procedures performed in the United States every year. There are various breast implant options, such as saline, silicone, smooth, and textured implants. Breast implant illness (BII) is a disorder associated with a wide array of symptoms presenting post breast implant surgery and is often associated with autoimmune disorders.
View Article and Find Full Text PDFSurg Endosc
September 2025
Department of Surgery and Cancer Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Introduction: This study aimed to evaluate surgeons' ergonomic satisfaction when using laparoscopic energy devices and to investigate how prolonged use affects muscle fatigue and surgical performance.
Methods: A two-part study, including a survey and a kinesiologic experiment, was conducted to compare 4 laparoscopic energy devices (D1-D4). Thirty surgeons completed a structured survey assessing ergonomic factors such as device weight, grip strength, handle design, comfort, and trigger location.
Pflugers Arch
September 2025
Department of Science, University "G. d'Annunzio" Chieti-Pescara, Chieti, Italy.
Hypoxia has been extensively studied as a stressor which pushes human bodily systems to responses and adaptations. Nevertheless, a few evidence exist onto constituent trains of motor unit action potential, despite recent advancements which allow to decompose surface electromyographic signals. This study aimed to investigate motor unit properties from noninvasive approaches during maximal isometric exercise in normobaric hypoxia.
View Article and Find Full Text PDFProc Biol Sci
September 2025
Division of Integrative Anatomical Sciences, University of Southern California Keck School of Medicine, Los Angeles, CA, USA.
Red blood cell (RBC) size constrains the rate of diffusion of gases between (i) the environment and the capillary beds of the gas exchanger and (ii) the blood and organs. In birds, small RBCs with a high surface area to volume ratio permit a high O diffusion capacity and facilitate sustained, vigorous exercise. Unfortunately, our knowledge of archosaur cardiovascular evolution is incomplete without fossilized RBCs and blood vessels.
View Article and Find Full Text PDFJ Neurophysiol
September 2025
Graduate School of Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 3868567, Japan.
This study investigated the correlation between the strength of correlated effective neural drive (END) to the antagonistic muscles and the fluctuations in neural/electrical and mechanical output around the joint during steady co-contraction, and whether the correlated END strength estimated from conventional surface EMG is correlated with that determined from motor unit (MU) discharges. Fourteen young male participants performed isometric steady co-contractions with their medial gastrocnemius and tibialis anterior muscles at 10% of maximal EMG while sitting. Correlated END strength was quantified as the maximum value of the cross-correlation function between the conventional surface EMG signals and between MU discharges decomposed from high-density surface EMG of each muscle.
View Article and Find Full Text PDF