Article Abstract

Objective: To evaluate the roles of surface electrocardiogram (ECG) and transthoracic echocardiography (ECHO) for prediction of atrial fibrillation (AF) after coronary artery bypass grafting (CABG).

Methods: This study was conducted from 2002-2004 at the Cardiovascular Department of Hacettepe University, Ankara, Turkey. Seventy consecutive patients were enrolled in this study that underwent elective CABG. A 12-lead ECG was recorded one day before cardiac surgery and was repeated during the 5 days after CABG. P-wave dispersion (PWD) was defined as the difference between maximum and minimum P-wave duration. Differences in P-wave duration were compared between the pre- and postoperative 12-lead ECG measurements.

Results: Postoperative AF developed in 17 (24%) cases of 70 patients. The PWD was found to be significantly higher in patients with AF preoperatively (60+/-19 versus 47+/-13, p=0.003), postoperative first day (56+/-12 versus 44+/-11, p<0.002) and fifth day (51+/-29 versus 41+/-11, p<0.001). Patients with AF were significantly older, the mean age of the AF group was (68+/-7) years and of the sinus rhythm (SR) group was (59+/-10 years) (p<0.001). The AF group had left ventricular systolic dysfunction (56+/-13% versus 56+/-8%, p=0.042, preoperatively; 49+/-8% versus 60+/-10%, p=0.001, postoperatively) and a larger left atrium (46+/-5 versus 39+/-5 mm, p<0.001, preoperatively and 44+/-7 versus 39+/-5 mm, p=0.046, postoperatively) than the SR group.

Conclusion: This prospective study demonstrated that PWD on surface ECG and additional echocardiographic parameters are simple and reliable indexes to predict the development of AF after CABG.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ecg transthoracic
8
transthoracic echocardiography
8
atrial fibrillation
8
fibrillation coronary
8
coronary artery
8
artery bypass
8
12-lead ecg
8
p-wave duration
8
role surface
4
ecg
4

Similar Publications

Background: Patent foramen ovale (PFO) has been identified as a potential risk factor for cryptogenic stroke (CS). Although transesophageal echocardiography (TEE) is considered the gold standard for PFO detection, false-negative results remain a clinical concern, particularly in CS patients with high suspicion of PFO-related etiology.

Aims: To evaluate the clinical utility of transcatheter PFO exploration (TPFOE) in CS patients with negative TEE findings but high suspicion of PFO-related etiology.

View Article and Find Full Text PDF

Background: Acute myocarditis is a potentially life-threatening cardiac condition and immediate assessment of this disease is imminent. While laboratory tests, electrocardiography or transthoracic echocardiography can provide indirect signs for the presence of acute myocarditis, cardiac magnetic resonance (CMR) imaging enables direct visualisation of myocardial inflammation and confirms the diagnosis.Since there is limited accessibility to CMR, the goal of this study was to evaluate the sensitivity and specificity of an elevation of established biomarkers for the diagnosis of myocarditis and to define a specific rule-out threshold for deferring CMR.

View Article and Find Full Text PDF

Background: Coronary artery pseudoaneurysms (CAP) are rare, especially without any history of coronary angioplasty and coronary bypass graft. The symptoms range from asymptomatic to cardiogenic shock. Because of its rarity and variable symptoms, patients with CAP should be treated with an individualized approach.

View Article and Find Full Text PDF

Background: Artificial intelligence (AI) applied to routine electrocardiograms (ECGs) offers promise for screening of structural heart disease (SHD), yet broad clinical integration remains limited by high false positive rates and the lack of tailored deployment strategies.

Methods: We developed TARGET-AI, a multimodal AI-enabled pipeline that integrates longitudinal electronic health record (EHR) data with ECG images to identify optimal intersections of healthcare encounters and patient phenotypes for targeted AI-ECG screening. The approach is built on (1) a foundation model pretrained on 118 million coded EHR events from 159,322 individuals to generate temporal patient embeddings and identify high-risk screening candidates, followed by (2) a contrastive vision-language model trained on 754,533 ECG-echocardiogram pairs to detect SHD with tunable performance characteristics.

View Article and Find Full Text PDF

Acute Pericarditis After Pulsed Field Ablation for Atrial Fibrillation.

JACC Case Rep

August 2025

Division of Cardiology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Republic of Korea. Electronic address:

Background: Pulsed field ablation (PFA) is a novel nonthermal ablation technique for atrial fibrillation, offering myocardial selectivity and a favorable safety profile. However, postprocedural pericarditis remains rarely reported.

Case Summary: A 62-year-old man with paroxysmal atrial fibrillation underwent PFA with intracardiac echocardiography.

View Article and Find Full Text PDF