A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Characteristics and outcome in patients receiving multiple (more than two) catheter ablation procedures for paroxysmal atrial fibrillation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The features of multiple catheter ablation procedures for paroxysmal atrial fibrillation (AF) are unknown. We aimed to investigate the electrophysiologic characteristics and the clinical outcomes in the patients with AF who received more than two ablation procedures.

Methods: The study consisted of 15 consecutive patients (age 48 +/- 14 years, 10 males) who had undergone three to five (3.3 +/- 0.6) catheter ablation procedures for recurrent paroxysmal AF.

Results: Ten patients had pulmonary vein (PV)-AF and one had AF originating from both PVs and the superior vena cava (SVC) in the first ablation procedure. All of them exhibited PV reconnection during the recurrent episodes. Four of the 15 patients had AF originating from non-PV foci (three from the SVC, one from the crista terminalis) in the first procedure, and two had AF recurrences due to recovered conduction from the SVC. In all patients with PV-AF recurrences, repeated PV isolation procedures could effectively eliminate the AF. The incidence of the need for additional LA linear ablation lesions was higher comparing between the first procedure and in the following ablation procedures (18% vs. 71%, P = 0.02). During a follow-up of 1.7 +/- 1.1 years, 73% of the patients remained in sinus rhythm without any antiarrhythmic drugs after the final procedure.

Conclusions: Recovered PV connection was the major cause of the AF recurrences despite undergoing multiple catheter ablation procedures. It is advisable to inspect all PVs during the AF recurrence. Repeated PV isolation plus left atrial linear ablations could effectively eliminate the AF with satisfactory outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2007.01012.xDOI Listing