98%
921
2 minutes
20
Objectives: To evaluate the inter-laboratory reproducibility of blood test for liver fibrosis: FibroMeter, Fibrotest, APRI and their composites variables.
Design And Methods: Four studies, including 147 patients, were performed: study #1 included 2 metachronous blood samples and 2 laboratories; studies #2, #3 and #4 included synchronous samples with assays delayed at day 1 in 12 laboratories, at day 0 in 10 laboratories and at day 0 or 1 in 2 laboratories, respectively. Agreement was evaluated by the intraclass correlation coefficient (r(ic)).
Results: In studies #1, #2 and #4, r(ic) for FibroMeter was 0.893, 0.942 and 0.991, respectively. In study #3, the r(ic) were: FibroMeter: 0.963, Fibrotest: 0.984, APRI: 0.949. Large simulated variations in composite variables had a weak impact on FibroMeter.
Conclusions: When blood marker limits are controlled, inter-laboratory agreement of blood tests is excellent in clinical practice conditions. Blood tests are robust against the variability of composite blood variables.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinbiochem.2007.08.009 | DOI Listing |
JAMA Dermatol
September 2025
Department of Dermatology, University of Washington, Seattle.
Importance: Merkel cell carcinoma (MCC) is typically caused by the Merkel cell polyomavirus (MCPyV) and recurs in 40% of patients. Half of patients with MCC produce antibodies to MCPyV oncoproteins, the titers of which rise with disease recurrence and fall after successful treatment.
Objective: To assess the utility of MCPyV oncoprotein antibodies for early detection of first recurrence of MCC in a real-world clinical setting.
J Magn Reson Imaging
September 2025
Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Background: Carotid artery stenosis is a major cause of stroke. Non-contrast MR angiography (MRA) using time-spatial labeling inversion pulse (Time-SLIP) may offer potential advantages over 3D time-of-flight (TOF)-MRA for simultaneous visualization of carotid, vertebral, and subclavian arteries, but remains uninvestigated.
Purpose: To determine optimal black blood inversion time (TI) for visualizing the carotid and subclavian arteries using three-dimensional (3D) fast field echo (FFE) Time-SLIP MRA, and to compare its image quality with 3D TOF-MRA.
Pediatr Crit Care Med
September 2025
Waisman Brain Imaging Laboratory, University of Wisconsin, Madison, WI.
Objectives: Elevated intracranial pressure (ICP) is a complication of severe traumatic brain injury (TBI) that carries a risk of secondary brain injury. This study investigated the association between ICP burden and brain injury patterns on MRI in children with severe TBI.
Design, Setting, And Patients: Secondary analysis of the Approaches and Decisions in Acute Pediatric TBI (ADAPT) study, which included children with severe TBI (Glasgow Coma Scale score < 9) who received a clinical MRI within 30 days of injury.
Sleep
September 2025
Center for Sleep Medicine, Hospices Civils de Lyon, Lyon 1 University, Lyon, F-69000, France.
Current treatments for narcolepsy type 1 (NT1) have little impact on psychiatric, cognitive and metabolic comorbidities. Here, we evaluated the feasibility, safety and efficacy of a prospective Exercise Training (ET) program on sleep-related symptoms and comorbidities in NT1. Sedentary adult with NT1 participated in a 6-week supervised ET program followed by a 18-week self-directed program.
View Article and Find Full Text PDFDan Med J
August 2025
Department of Hepatology and Gastroenterology, Aarhus University Hospital.
Introduction: A no-biopsy approach has been suggested for diagnosing coeliac disease (CD) in adult patients. This approach is already well established in diagnosing children with CD. This study aimed to evaluate the accuracy of IgA anti-tissue transglutaminase (IgA anti-tTG) in predicting duodenal mucosal lesions diagnostic of CD in adult patients.
View Article and Find Full Text PDF