A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Permanent pacemaker for atrioventricular conduction block after operative repair of perimembranous ventricular septal defect. | LitMetric

Permanent pacemaker for atrioventricular conduction block after operative repair of perimembranous ventricular septal defect.

J Am Coll Cardiol

Division of Pediatric Cardiology, Department of Pediatrics, University of Minnesota, Minneapolis, Minnesota 55455, USA.

Published: September 2007


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: This study sought to discover the incidence of permanent pacemaker (PPM) placement for atrioventricular conduction block (AV block) after operative repair of perimembranous ventricular septal defect (PMVSD) in a large multi-institutional database and in the subgroup of patients comparable to those considered for transcatheter device closure of PMVSD.

Background: Atrioventricular conduction block is a complication of operative repair of PMVSD and of device closure of this defect. Earlier reports do not report the incidence of AV block by VSD type.

Methods: The Pediatric Cardiac Care Consortium database was searched for all children who had operative PMVSD repair except those with abnormalities that increase risk of AV block. The patient group was searched for those with subsequent PPM placement for AV block. Demographic data and time to PPM placement were available for all patients.

Results: Of 4,432 patients with PMVSD repair, 48 (1.1%) underwent PPM placement for AV block. The PPM group was more likely to have Down syndrome (41% vs. 18%; p < 0.001), was younger (mean age 14 vs. 26 months; p < 0.001), and had longer mean length of postoperative hospital stays (20 vs. 8 days; p < 0.001). The most significant risk factor for AV block was Down syndrome (odds ratio 3.62, 95% confidence interval 2.02 to 6.39; p < 0.005). Modal time to PPM placement was 7 days (range 0 to 4,078 days). Out of 1,877 patients comparable to those currently considered for device closure, 13 (0.8%) underwent PPM placement after PMVSD repair.

Conclusions: Operative AV block and PPM placement occurred in 1.1% of patients in the total group and in 0.8% of patients comparable to those considered for device closure of PMVSD. A PPM placement is more likely in patients with Down syndrome. These data should be considered as devices are developed and in the future when counseling families about options for PMVSD closure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2007.06.014DOI Listing

Publication Analysis

Top Keywords

ppm placement
32
device closure
16
atrioventricular conduction
12
conduction block
12
operative repair
12
patients comparable
12
block
10
ppm
9
permanent pacemaker
8
block operative
8

Similar Publications