Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
A new method was developed and validated for the simultaneous determination of 151 pesticide residues in strawberry by gas chromatography coupled to a triple quadrupole mass analyzer (GC/QqQ-MS/MS), mainly using the selected reaction monitoring (SRM) mode. The list of target compounds included various classes of pesticides such as organochlorine (OCPs), organophosphorus (OPPs), carbamates, pyrethroids, triazoles and dicarboximides. A single extraction of 10 g of sample with acetonitrile followed by liquid-liquid partition formed by the addition of 4 g of MgSO4 and 1 g of NaCl was applied in sample preparation. Cleanup of the extracts was carried out by applying dispersive solid-phase extraction (D-SPE) with primary secondary amine (PSA). The analysis time was 21 min. The method was subjected to a thorough validation procedure. The recovery data were obtained by spiking blank samples at two concentration levels (11.5 and 50 microg/kg), yielding recoveries in the range 70-110%. Precision values expressed as relative standard deviation (RSD) were lower than 18% and 22% for the intraday and interday precision, respectively. Linearity was studied in the range 10-200 microg/kg and determination coefficients (R(2)) were higher than 0.98% for all compounds. Limits of detection (LODs) and limits of quantification (LOQs) were established as 4 and 10 microg/kg, respectively. The overall uncertainty of the method was estimated at two different concentrations (11.5 and 50 microg/kg), being lower than 25% in both cases. According to the validation data and performance characteristics as well as the high sample throughput and low cost, the proposed method is suitable for routine application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/rcm.3091 | DOI Listing |