A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Surface plasmon resonance-based trace detection of small molecules by competitive and signal enhancement immunoreaction. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A surface plasmon resonance (SPR)-immunosensor for detection of the low molecular weight compound 2,4-dinitorophenol (DNP) at ultra-low concentration has been developed. The sensor strategy is based on a competitive immunoreaction between DNP and a DNP-protein conjugate, namely DNP-bovine serum albumin conjugate (DNP-BSA). Anti-DNP monoclonal antibody was immobilized on a gold thin-film coated SPR-sensor chip by means of a chemical coupling process. DNP-BSA, on contact with the anti-DNP antibody immobilized SPR-immunosensor chip causes an increase in the resonance angle of the sensor chip. The optimum concentration of immobilized antibody on the SPR-sensor chip is 100 microg mL(-1). The SPR-immunosensor response for free DNP determination using the competitive immunoreaction had a response time of ca. 15 min. Using this method, DNP could be determined in the concentration range 1 ppt to 1 ppb. The SPR signal for ppt levels of DNP was enhanced by a factor of three by subsequently treating immuno-bound DNP-BSA with a secondary anti-DNP antibody.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2007.03.074DOI Listing

Publication Analysis

Top Keywords

surface plasmon
8
competitive immunoreaction
8
antibody immobilized
8
spr-sensor chip
8
anti-dnp antibody
8
dnp
5
plasmon resonance-based
4
resonance-based trace
4
trace detection
4
detection small
4

Similar Publications