Mechanism of action of a flavin-containing monooxygenase.

Proc Natl Acad Sci U S A

Biology Department, Brookhaven National Laboratory, Upton, NY 11973, USA.

Published: June 2006


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Elimination of nonnutritional and insoluble compounds is a critical task for any living organism. Flavin-containing monooxygenases (FMOs) attach an oxygen atom to the insoluble nucleophilic compounds to increase solubility and thereby increase excretion. Here we analyze the functional mechanism of FMO from Schizosaccharomyces pombe using the crystal structures of the wild type and protein-cofactor and protein-substrate complexes. The structure of the wild-type FMO revealed that the prosthetic group FAD is an integral part of the protein. FMO needs NADPH as a cofactor in addition to the prosthetic group for its catalytic activity. Structures of the protein-cofactor and protein-substrate complexes provide insights into mechanism of action. We propose that FMOs exist in the cell as a complex with a reduced form of the prosthetic group and NADPH cofactor, readying them to act on substrates. The 4alpha-hydroperoxyflavin form of the prosthetic group represents a transient intermediate of the monooxygenation process. The oxygenated and reduced forms of the prosthetic group help stabilize interactions with cofactor and substrate alternately to permit continuous enzyme turnover.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1502539PMC
http://dx.doi.org/10.1073/pnas.0602398103DOI Listing

Publication Analysis

Top Keywords

prosthetic group
20
mechanism action
8
protein-cofactor protein-substrate
8
protein-substrate complexes
8
nadph cofactor
8
form prosthetic
8
prosthetic
5
group
5
action flavin-containing
4
flavin-containing monooxygenase
4

Similar Publications

Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study.

J Prosthet Dent

September 2025

Assistant Professor, Department of Prosthetic Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACEA, UMR 5199, Pessac, France. Electronic address:

Statement Of Problem: The reproducibility of positioning the maxillary occlusal plane in an articulator with a facebow remains debated. Its clinical use is widespread, yet its reliability and clinical outcomes compared to other transfer methods under standardized conditions remain uncertain.

Purpose: The purpose of this in vitro study was to compare the intra-operator reproducibility of maxillary positioning on an articulator using a facebow compared to a standardized transfer table.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.

Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.

View Article and Find Full Text PDF

Purpose: To compare the accuracy of static guided surgery using a pilot drill guide and dynamic guided surgery for dental implant placement.

Materials And Methods: Partially edentulous adult patients requiring implant placement were randomly assigned to either the static guided surgery group using a pilot drill guide or the dynamic guided surgery group. Digital implant planning was conducted using intraoral scans and CBCT with planning software to determine the optimal prosthetic position.

View Article and Find Full Text PDF

Background: Certain 3D interrelationships between adjacent implants can potentially predispose to prosthetic and biological complications.

Materials And Methods: Patient records with adjacent dental implants were assessed to evaluate the effects of vertical, horizontal and angulation interrelationships between splinted compared to non-splinted implant restorations on the occurrence of biological and prosthetic complications. Data on patient- and implant-related variables were collected at baseline (T1) during prosthesis placement and at the last follow-up appointment (T2).

View Article and Find Full Text PDF

Background: Over the past few decades, technological advancements have transformed invasive visual prostheses from theoretical concepts into real-world applications. However, functional outcomes remain limited, especially in visual acuity. This review aims to summarize current developments in retinal and cortical prostheses (RCPs) and critically assess the role of artificial intelligence (AI) in advancing these systems.

View Article and Find Full Text PDF