Article Abstract

Object: Implantation of a subthalamic nucleus (STN) deep brain stimulation (DBS) electrode is increasingly recognized as an effective treatment for advanced Parkinson disease (PD). Despite widespread use of microelectrode recording (MER) to delineate the boundaries of the STN prior to stimulator implantation, it remains unclear to what extent MER improves the clinical efficacy of this procedure. In this report, the authors analyze a series of patients who were treated at one surgical center to determine to what degree final electrode placement was altered, based on readings obtained with MER, from the calculated anatomical target.

Methods: Subthalamic DBS devices were placed bilaterally in nine patients with advanced PD. Frame-based volumetric magnetic resonance images were acquired and then transferred to a stereotactic workstation to determine the anterior and posterior commissure coordinates and plane. The initial anatomical target was 4 mm anterior, 4 mm deep, and 12 mm lateral to the midcommissural point. The MERs defined the STN boundaries along one or more parallel tracks, refining the final electrode placement by comparison of results with illustrations in a stereotactic atlas. In eight of 18 electrodes, the MER results did not prompt an alteration in the anatomically derived target. In another eight placements, MER altered the target by less than 1 mm and two of 18 electrode positions differed by less than 2 mm. The anterior-posterior difference was 0.53 +/- 0.65 mm, whereas the medial-lateral direction differed by 0.25 +/- 0.43 mm. The ventral boundary of the STN defined by MER was 2 +/- 0.72 mm below the calculated target (all values are the means +/- standard deviation). All patients attained clinical improvement, similar to previous reports.

Conclusions: In this series of patients, microelectrode mapping of the STN altered the anatomically based target only slightly. Because it is not clear whether such minor adjustments improve clinical efficacy, a prospective clinical comparison of MER-refined and anatomical targeting may be warranted.

Download full-text PDF

Source
http://dx.doi.org/10.3171/foc.2006.20.5.9DOI Listing

Publication Analysis

Top Keywords

anatomically based
8
microelectrode recording
8
clinical efficacy
8
series patients
8
final electrode
8
electrode placement
8
mer
6
electrode
5
stn
5
target
5

Similar Publications

Background: Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.

Materials And Methods: In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.

View Article and Find Full Text PDF

Objective: We hypothesized that anatomic location of metastatic melanoma is associated with the degree of therapeutic response to TVEC.

Summary: TVEC is the first FDA-approved injectable oncolytic virus to treat unresectable stage IIIB-IV metastatic melanoma patients. Previously published real-world outcomes demonstrated a 39% complete response (CR) rate to TVEC.

View Article and Find Full Text PDF

Objective: The incidence of total shoulder arthroplasty (TSA) in the United States continues to climb as an aging yet active population increases demand for the procedure. Due to promising clinical results out of Europe, improvement in prosthesis design, and wider acceptance of reverse total shoulder arthroplasty (rTSA), this study was designed to evaluate how rTSA and anatomical TSA (aTSA) utilization, patient selection, and length of stay have changed at a single institution.

Methods: This was a retrospective cohort study of patients from one hospital system between 2017 and 2023.

View Article and Find Full Text PDF

Digital twins in nuclear medicine: A proposition of a modular pipeline for dosimetry protocol optimization in molecular radiotherapy.

Comput Struct Biotechnol J

August 2025

Institut de Recherche en Cancérologie de Montpellier (IRCM), Équipe Labellisée Ligue Contre le Cancer, INSERM U1194, Université de Montpellier, Institut régional du Cancer de Montpellier (ICM), Montpellier, France.

Digital twins (DTs) are emerging tools for simulating and optimizing therapeutic protocols in personalized nuclear medicine. In this paper, we present a modular pipeline for constructing patient-specific DTs aimed at assessing and improving dosimetry protocols in PRRT such as therapy. The pipeline integrates three components: (i) an anatomical DT, generated by registering patient CT scans with an anthropomorphic model; (ii) a functional DT, based on a physiologically-based pharmacokinetic (PBPK) model created in SimBiology; and (iii) a virtual clinical trial module using GATE to simulate particle transport, image simulation, and absorbed dose distribution.

View Article and Find Full Text PDF

Cardiopulmonary resuscitation (CPR) is a critical, life-saving intervention. In pregnant women, unique anatomical and physiological changes require adaptations to standard CPR protocols to ensure optimal outcomes for both mother and fetus, emphasizing the need for universal awareness and standardized training across diverse healthcare systems globally. Despite the high-risk nature of maternal cardiac arrest, evidence suggests that many healthcare professionals may not be adequately prepared to respond effectively.

View Article and Find Full Text PDF