Article Abstract

Purpose: To evaluate objective functional and radiographic outcomes after internal fixation of acute, displaced, and unstable fractures of the distal aspect of the radius in adults by using a low-profile dorsal plating system. Our hypothesis was that the low-profile dorsal plating system would allow for a reduction of extensor tendon irritation and pain and provide stable osseous fixation.

Methods: Sixty consecutive unstable fractures in 59 patients were treated by open reduction internal fixation using a low-profile dorsal plating system. There were 29 type A, 14 type B, and 8 type C fractures (AO classification system). Fifty patients with 51 fractures returned for outcomes assessment by physical examination, plain radiographs, and completion of a validated musculoskeletal function assessment questionnaire. The minimum follow-up period was 1 year; the mean follow-up period was 24 months. Clinical evaluation was performed and plain radiographs were assessed for maintenance of immediate postoperative reduction and implant position. Objective functional assessment was obtained through the Disabilities of the Arm, Shoulder, and Hand questionnaire.

Results: Outcomes analysis showed no cases of extensor tendon irritation or rupture. Hardware removal was performed in 1 patient but no extensor tendon irritation or rupture was evidenced. The mean Disabilities of the Arm, Shoulder, and Hand score was 11.9; implant-related discomfort was minimal. All patients had an excellent (31 patients) or good (19 patients) result according to the scoring system of Gartland and Werley. The mean active range of motion was greater than 80% of that of the contralateral wrist in flexion/extension, pronation/supination, and ulnar/radial deviation. Extensor tendon function was unimpaired in all patients. Grip and pinch strength averaged 90% and 94% of the contralateral sides, respectively. Radiographic evaluation showed no change in fracture reduction or implant position.

Conclusions: The treatment of distal radius fractures with a low-profile stainless steel dorsal plating system is a safe and effective method that provides stable internal fixation and allows for full extensor tendon glide and full metacarpophalangeal joint motion. Objective outcome testing showed uniformly good to excellent recovery of wrist and hand function in all patients.

Type Of Study/level Of Evidence: Therapeutic, Level IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2005.10.016DOI Listing

Publication Analysis

Top Keywords

dorsal plating
20
plating system
20
extensor tendon
20
low-profile dorsal
16
internal fixation
12
tendon irritation
12
treatment distal
8
distal radius
8
radius fractures
8
fractures low-profile
8

Similar Publications

Capitate Osteochondral Graft for Reconstruction of Unstable Proximal Interphalangeal Joint Injury.

JBJS Essent Surg Tech

September 2025

Division of Hand and Reconstructive Microsurgery, Department of Orthopedics, Olympia Hospital & Research Centre, Trichy, Tamilnadu, India.

Background: Hemi-hamate osteochondral grafting is a surgical technique that is utilized to reconstruct the proximal interphalangeal (PIP) joint in cases of unstable dorsal fracture-dislocation with >50% articular surface involvement. However, hemi-hamate osteochondral grafting can be technically challenging, has been reported to have various technical modifications, and can lead to complications such as overstuffing of the joint. This surgical technique article describes successful PIP joint reconstruction with use of a hemi-capitate osteochondral graft, which may offer a viable alternative to hemi-hamate osteochondral graft.

View Article and Find Full Text PDF

Background: Dorsal wrist spanning plate (DWSP) fixation in distal radius fractures (DRFs) has been proposed to allow earlier mobilization in polytraumatized patients by enabling early weightbearing (WB) through the injured wrist. The purpose of this study is to compare radiographic and clinical outcomes in patients who bore weight through the injured wrist within the early postoperative period with patients who did not bear weight.

Methods: Patients who underwent DWSP fixation at a single institution were retrospectively identified.

View Article and Find Full Text PDF

Selective inhibition of histone deacetylase 3 (HDAC3) prevents vincristine-induced peripheral neuropathy via macrophage polarization.

Neuropharmacology

September 2025

Metabolic Disorders and Neuroscience Research Laboratory, Department of Pharmacy, Birla Institute of Technology and Sciences Pilani, Hyderabad Campus, Hyderabad, India. Electronic address:

Neuroinflammation is vital in vincristine-induced peripheral neuropathy (VIPN). Locally infiltrated macrophages polarize to pro-inflammatory M1-type, release inflammatory cytokines, and contribute to neuropathic pain. Histone deacetylase 3 (HDAC3) regulates macrophage polarization.

View Article and Find Full Text PDF

Background: The optimal management of distal radius fractures (DRFs) in older patients remains debatable. A knowledge gap exists concerning how to manage fractures with early malalignment during nonoperative treatment. We conducted a prospective, multicenter, and randomized controlled trial to compare nonoperative treatment to operative treatment with volar locking plating (VLP) in the management of primarily malaligned DRFs and DRFs that exhibit early malalignment during nonoperative treatment.

View Article and Find Full Text PDF

Gill-skeleton modifications for processing prey represent a major source of functional innovation in living ray-finned fishes. Here we present the oldest actinopterygian tongue bite, derived from the gill skeleton, in the Middle Pennsylvanian (approx. 310 Ma) †.

View Article and Find Full Text PDF