Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
ELISA methods have been developed for screening contamination of water resources by linear alkyl benzene sulfonates (LAS) or the most immediate degradation products, the long chain sulfophenyl carboxylates, SPCs. The assay uses antibodies raised through pseudoheterologous immunization strategies using an equimolar mixture of two immunogens (SFA-KLH and 13C(13)-SPC-KLH) prepared by coupling N-(4-alkylphenyl)sulfonyl-3-aminopropanoic acid (SFA) and p-(1-carboxy-13-tridecyl)phenylsulfonic acid (13C(13)-SPC) to keyhole limpet hemocyanin (KLH). The immunizing haptens have been designed to address recognition versus two different epitopes of the molecule. The SFA hapten maximizes recognition of the alkyl moiety while preserving the complexity of the different alkyl chains present in the LAS technical mixture. The 13C(13)-SPC hapten addresses recognition of the common and highly antigenic phenylsulfonic group. The antisera raised using this strategy have been shown to be superior to those obtained through homologous immunization procedures using a single substance. By using an indirect ELISA format, LAS and long-chain SPCs can be detected down to 1.8 and 0.2 microg L(-1), respectively. Coefficients of variation of 6 and 12% within and between assays, respectively, demonstrate immunoassay reproducibility. The assay can be used in media with a wide range of pH and ionic strength values. Preliminary experiments performed to assess matrix effects have demonstrated the potential applicability of the method as a screening tool to assess contamination by these types of surfactants in natural water samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac051141s | DOI Listing |