A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Detecting ATP release by a biosensor method. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cells release adenosine 5'-triphosphate (ATP) into the extracellular space in response to various stimuli. This released ATP plays an important physiological role in cell-to-cell signal transduction. The bulk ATP concentration can be detected using a conventional luciferin-luciferase assay. However, the ATP concentration in the vicinity of the cell surface is often different from the bulk concentration because of its rapid degradation by ecto-ATPases and because of delayed diffusion due to unstirred layer effects. Here, we describe a simple biosensor method to measure the local ATP concentration on the cell surface in real time. The method is based on the ATP-dependent opening of ligand-gated cation channels of purinergic P2X receptors expressed in undifferentiated pheochromocytoma (PC12) cells or in human embryonic kidney 293 (HEK293) cells stably transfected with recombinant P2X2 purinergic receptors. Under the whole-cell configuration of patch-clamp, a sensor PC12 cell or HEK293 is positioned within the proximity of a target cell, and the P2X-mediated currents induced by ATP released from a given site on the target cell surface is measured. The ATP release is quantified by a calibration procedure utilizing local puff applications of ATP at preset concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1126/stke.2582004pl14DOI Listing

Publication Analysis

Top Keywords

atp concentration
12
cell surface
12
atp release
8
biosensor method
8
atp
8
target cell
8
cell
5
detecting atp
4
release biosensor
4
method cells
4

Similar Publications