A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study evaluated the marginal fit of experimental and custom-made fixed prosthetic restorations through a new 360-degree external examination. The minimum number of gap measurements required to produce relevant results for gap analysis was also investigated.

Materials And Methods: The marginal fit of six experimental and eight custom-made crowns was observed microscopically by means of a mechanical device, and software was employed to measure the gap. Two crowns, chosen from among the 14 previously evaluated, were reanalyzed to determine the minimum number of gap measurements required to produce significant results for gap analysis.

Results: The precision obtained with the custom-made crowns differed from that of the experimental specimens. The minimum number of measurements required to produce a sample mean value within +/- 5 microm of the mean, calculated over 360 measurements, taking standard error of the means < or = 4 microm, was 18 for experimental and 90 for custom-made crowns, for both equidistant measurement spacing and randomly selected points.

Conclusion: Differences in fit between experimental specimens and custom-made ones showed that experimental results might not always be obtained in clinical practice. Within the limitations of the protocol of this study, the minimum number of measurements required to ensure relevant results for gap analysis was 18 for experimental and 90 for custom-made crowns.

Download full-text PDF

Source

Publication Analysis

Top Keywords

experimental custom-made
16
minimum number
16
measurements required
16
custom-made crowns
16
fit experimental
12
required produce
12
360-degree external
8
external examination
8
marginal fit
8
number gap
8

Similar Publications