A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Complications associated with cannula insertion techniques used for laparoscopy in standing horses. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To report our experience and complications associated with different cannula insertion techniques for laparoscopy in standing horses.

Study Design: Retrospective study.

Sample Population: Forty horses that had laparoscopy for diagnostic or surgical purposes.

Methods: After a physical examination, including rectal palpation, standing laparoscopy was performed in 40 sedated horses. Local anesthetic was injected at each site of cannula insertion in the left flank. Horses were divided into 5 groups: Pneumoperitoneum was induced before cannula insertion using a Verres needle (group 1, n = 3) or a 12-g catheter (group 2, n = 14); the cannula was inserted before inducing a pneumoperitoneum (group 3, n = 9); the cannula was inserted under visual control, using an operating laparoscope (group 4, n = 2) or a Visiport Optical Trocar (group 5, n = 12). Horses were observed for 7 days.

Results: Problems with insufflation or cannula insertion occurred in 12 horses: 6 had peritoneal detachment, 4 had a splenic puncture, and 2 had descending colon puncture. Eleven of these complications occurred in groups 1 to 3 and only 1 in groups 4 and 5.

Conclusions: The Visiport optical device allows controlled insertion of the initial trocar, and thus avoided potential problems associated with "blind" cannula insertion techniques and was used effectively in horses that had feed withheld for 12 hours. This technique enables direct insertion of a cannula directly into the right flank.

Clinical Relevance: Complications associated with initial cannula insertion in the paralumbar fossa, for laparoscopy, in standing horses can be minimized with the use of an optical cannula.

Download full-text PDF

Source
http://dx.doi.org/10.1053/jvet.2003.50057DOI Listing

Publication Analysis

Top Keywords

cannula insertion
28
complications associated
12
insertion techniques
12
laparoscopy standing
12
cannula
11
insertion
9
associated cannula
8
techniques laparoscopy
8
horses
8
standing horses
8

Similar Publications