Publications by authors named "Vincent B Ho"

The MAGNUS high-performance MRI gradient platform delivers G = 200-300 mT/m, and SR = 500-750 T/m/s using standard clinical 3.0T system power electronics. This enables the exploration of an expanded diffusion parameter space (b~7-≥30 ms/μm) with reasonable SNR, along with substantially shorter diffusion encoding pulse-widths, echo times, reduced distortion, and blurring from shorter echo spacing.

View Article and Find Full Text PDF

Conducted in challenging environments such as disaster or conflict areas, operational medicine presents unique challenges for the delivery of efficient and quality healthcare. It exposes first responders and medical personnel to many unexpected health risks and dangerous situations. To tackle these issues, artificial intelligence (AI) has been progressively incorporated into operational medicine, both on the front lines and also more recently in support roles.

View Article and Find Full Text PDF

A phase-sensitive diffusion tensor magnetic resonance imaging (MRI) sequence is proposed with pulse timing optimization scheme to achieve velocity resolution of less than 20μm s and an integrated image reconstruction and velocity map generation pipeline. The application of ultra-slow flow relevant to neurofluids is enabled by the use of a recently developed, ultra-high-performance brain MRI gradient system. By simultaneously reconstructing magnitude and phase data, both metrics that characterize diffusive fluid motion and coherent velocity maps are calculated non-invasively in human subjects, time-resolved over the entire cardiac cycle.

View Article and Find Full Text PDF

A reliable, accessible, and high-quality blood supply is critical for the sustainment of any healthcare system. World events such as the COVID-19 pandemic have proven that maintaining the supply of blood presents a logistical challenge. The current blood supply is overseen by extensive donor programs around the world.

View Article and Find Full Text PDF

We bioprinted meniscus tissue on the International Space Station (ISS) using the onboard BioFabrication Facility (BFF). The three dimensional (3D) printing bioink, cells, culture media and fixative were delivered to the ISS on NG-18 and SpX-27 vehicles and stored prior to the printing operation. The meniscus tissue was fabricated from ink composed of collagens type I and II, chondroitin sulfate and mesenchymal stem cells.

View Article and Find Full Text PDF

Skin wounds often form scar tissue during healing. Early intervention with tissue-engineered materials and cell therapies may promote scar-free healing. Exosomes and extracellular vesicles (EV) secreted by mesenchymal stromal cells (MSC) are believed to have high regenerative capacity.

View Article and Find Full Text PDF

Medical response to military conflicts, natural disasters, and humanitarian crises are challenged by operational logistics with unreliable supply chains, delayed medical evacuation, and compatibility of the disparate medical equipment and consumables. In these environments, stocks of supplies will become more quickly depleted and the need for equipment parts increases secondary to their higher likelihood for failure from overuse. Additive Manufacturing (AM), or 3D printing, at or closer to the point-of-need provides potential solutions to mitigate these logistics challenges.

View Article and Find Full Text PDF

Micro-computed tomography (microCT) is a common tool for the visualization of the internal composition of organic tissues. Collagen comprises approximately 25-35% of the whole-body protein content in mammals, and the structure and arrangement of collagen fibers contribute significantly to the integrity of tissues. Collagen type I is also frequently used as a key structural component in tissue-engineered and bioprinted tissues.

View Article and Find Full Text PDF

Mild traumatic brain injury (mTBI) is a significant health burden among military service members. Although mTBI was once considered relatively benign compared to more severe TBIs, a growing body of evidence has demonstrated the devastating neurological consequences of mTBI, including chronic post-concussion symptoms and deficits in cognition, memory, sleep, vision, and hearing. The discovery of reliable biomarkers for mTBI has been challenging due to under-reporting and heterogeneity of military-related mTBI, unpredictability of pathological changes, and delay of post-injury clinical evaluations.

View Article and Find Full Text PDF

Injuries to the meniscus are common and can impair physical activities. Bioprinted meniscal tissue offers an attractive alternative to donor tissue for meniscal repair but achieving the strength of native tissue is a challenge. Here we report the development of a tissue engineering bioreactor designed to apply repetitive force which may lead to an increase in the compressive modulus and durability of bioprinted meniscal tissues.

View Article and Find Full Text PDF

Purpose: We hypothesized that the time-dependent diffusivity at short diffusion times, as measured by oscillating gradient spin echo (OGSE) diffusion MRI, can characterize tissue microstructures in glioma patients.

Theory And Methods: Five adult patients with known diffuse glioma, including two pre-surgical and three with new enhancing lesions after treatment for high-grade glioma, were scanned in an ultra-high-performance gradient 3.0T MRI system.

View Article and Find Full Text PDF

Shiga toxins (Stxs) produced by ingested can induce hemolytic uremic syndrome after crossing the intact intestinal barrier, entering the bloodstream, and targeting endothelial cells in the kidney. The method(s) by which the toxins reach the bloodstream are not fully defined. Here, we used two polarized cell models to evaluate Stx translocation: (i) a single-layer primary colonic epithelial cell model and (ii) a three-cell-layer model with colonic epithelial cells, myofibroblasts, and colonic endothelial cells.

View Article and Find Full Text PDF

Introduction: Known as the "golden hour," survival of most critically injured patients is highly dependent on providing the required treatment within the first hour of injury. Recent technological advances in additive manufacturing (also known as three-dimensional [3D] printing) allow for austere deployment and point-of-care rapid fabrication of a variety of medical supplies, including human tissues and bioactive bandages, in prolonged field care scenarios. In this pilot project, our aim was to investigate the ability to 3D print a range of potential biomedical supplies and solutions in an austere field environment.

View Article and Find Full Text PDF
Article Synopsis
  • The study discusses the challenges posed by asymmetric gradient coils in MRI, particularly focusing on the need for accurate calibration of concomitant field parameters.
  • A new method utilizing a modified phase contrast pulse sequence with single-sided bipolar flow encoding is introduced for efficient one-time calibration of these parameters.
  • Results show significant improvements in image quality and reduction of artifacts in MRI scans, demonstrating the effectiveness of the proposed calibration technique for enhancing real-time imaging without extensive modifications.
View Article and Find Full Text PDF

Background And Aims: Sleepiness influences alertness and cognitive functioning and impacts many aspects of medical care, including clinical reasoning. However, dual processing theory suggests that sleepiness will impact clinical reasoning differently in different individual, depending on their level of experience with the given condition. Our aim, therefore, was to examine the association between clinical reasoning, neuroanatomical activation, and sleepiness in senior medical students.

View Article and Find Full Text PDF

The meniscus is a key stabilizing tissue of the knee that facilitates proper tracking and movement of the knee joint and absorbs stresses related to physical activity. This review article describes the biology, structure, and functions of the human knee meniscus, common tears and repair approaches, and current research and development approaches using modern methods to fabricate a scaffold or tissue engineered meniscal replacement. Meniscal tears are quite common, often resulting from sports or physical training, though injury can result without specific contact during normal physical activity such as bending or squatting.

View Article and Find Full Text PDF

Introduction: Traditionally, tissue engineering techniques have largely focused on 2D cell culture models-monolayers of immortalized or primary cells growing on tissue culture plastic. Although these techniques have proven useful in research, they often lack physiological validity, because of the absence of fundamental tissue properties, such as multicellular organization, specialized extracellular matrix structures, and molecular or force gradients essential to proper physiological function. More recent advances in 3D cell culture methods have facilitated the development of more complex physiological models and tissue constructs; however, these often rely on self-organization of cells (bottom-up design), and the range of tissue construct size and complexity generated by these methods remains relatively limited.

View Article and Find Full Text PDF

Purpose: We investigate the importance of high gradient-amplitude and high slew-rate on oscillating gradient spin echo (OGSE) diffusion imaging for human brain imaging and evaluate human brain imaging with OGSE on the MAGNUS head-gradient insert (200 mT/m amplitude and 500 T/m/s slew rate).

Methods: Simulations with cosine-modulated and trapezoidal-cosine OGSE at various gradient amplitudes and slew rates were performed. Six healthy subjects were imaged with the MAGNUS gradient at 3T with OGSE at frequencies up to 100 Hz and b = 450 s/mm .

View Article and Find Full Text PDF

Purpose: To develop a highly efficient magnetic field gradient coil for head imaging that achieves 200 mT/m and 500 T/m/s on each axis using a standard 1 MVA gradient driver in clinical whole-body 3.0T MR magnet.

Methods: A 42-cm inner diameter head-gradient used the available 89- to 91-cm warm bore space in a whole-body 3.

View Article and Find Full Text PDF

Purpose: To establish peripheral nerve stimulation (PNS) thresholds for an ultra-high performance magnetic field gradient subsystem (simultaneous 200-mT/m gradient amplitude and 500-T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42-cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks.

Methods: The MAGNUS head gradient was installed in a whole-body 3T scanner with a custom 16-rung bird-cage transmit/receive RF coil compatible with phased-array receiver brain coils. Twenty adult subjects (10 male, mean ± SD age = 40.

View Article and Find Full Text PDF

Objectives: This work describes customized, task-specific simulation models derived from 3D printing in clinical settings and medical professional training programs.

Methods: Simulation models/task trainers have an array of purposes and desired achievements for the trainee, defining that these are the first step in the production process. After this purpose is defined, computer-aided design and 3D printing (additive manufacturing) are used to create a customized anatomical model.

View Article and Find Full Text PDF

Cardiovascular imaging with calcium scoring computed tomography (CT), coronary CT angiography (CCTA), and cardiac MRI (CMR) have advanced rapidly over recent years. These imaging modalities have increased in availability, accessibility, and clinical practicality due to technological advances allowing for significant radiation dose reduction for high-quality CCTA and for rapid and reliable imaging techniques in CMR. Hardware and software developments are continually increasing efficiency and accuracy of postprocessing.

View Article and Find Full Text PDF

In patients with chronic chest pain in the setting of high probability of coronary artery disease (CAD), imaging has major and diverse roles. First, imaging is valuable in determining and documenting the presence, extent, and severity of myocardial ischemia, hibernation, scarring, and/or the presence, site, and severity of obstructive coronary lesions. Second, imaging findings are important in determining the course of management of patients with suspected chronic myocardial ischemia and better defining those patients best suited for medical therapy, angioplasty/stenting, or surgery.

View Article and Find Full Text PDF

The incidence of congenital heart disease (CHD) has been increasing in the adult patient population in part as a result of better patient survival. Patients with more severe CHD are living longer. Nearly all adults with known CHD require periodic imaging as a means of monitoring their disease process.

View Article and Find Full Text PDF

Background: The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities.

View Article and Find Full Text PDF