Liquid biopsy, through isolation and analysis of disease-specific analytes, has evolved as a promising tool for safe and minimally invasive diagnosis and monitoring of tumors. It also has tremendous utility as a companion diagnostic allowing detection of biomarkers in a range of cancers (lung, breast, colon, ovarian, brain). However, clinical implementation and validation remains a challenge.
View Article and Find Full Text PDFThe emerging field of liquid biopsy stands at the forefront of novel diagnostic strategies for cancer and other diseases. Liquid biopsy allows minimally invasive molecular characterization of cancers for diagnosis, patient stratification to therapy, and longitudinal monitoring. Liquid biopsy strategies include detection and monitoring of circulating tumor cells, cell-free DNA, and extracellular vesicles.
View Article and Find Full Text PDFCirculating tumor cells (CTCs) and cancer-associated fibroblasts (CAFs) from whole blood are emerging as important biomarkers that potentially aid in cancer diagnosis and prognosis. The microfilter technology provides an efficient capture platform for them but is confounded by two challenges. First, uneven microfilter surfaces makes it hard for commercial scanners to obtain images with all cells in-focus.
View Article and Find Full Text PDFMethods Mol Biol
April 2018
Microfilters with slot-pore geometry can be used for size-based capture of circulating tumor cells (CTC) from the blood of cancer patients. The slot pore geometry reduces the shear stress that the cells would typically experience during filtration process and allows the cells to remain viable. The microfilter provides a platform capable of high CTC capture efficiency; however, the release of these cells from the filter following capture is nontrivial, possibly due to the strong nonspecific electrostatic adhesion of CTC to the microfilter surface.
View Article and Find Full Text PDFAnnu Rev Anal Chem (Palo Alto Calif)
June 2017
Circulating tumor cells (CTCs) are shed from the primary tumor into the circulatory system and act as seeds that initiate cancer metastasis to distant sites. CTC enumeration has been shown to have a significant prognostic value as a surrogate marker in various cancers. The widespread clinical utility of CTC tests, however, is still limited due to the inherent rarity and heterogeneity of CTCs, which necessitate robust techniques for their efficient enrichment and detection.
View Article and Find Full Text PDFWe report the design and fabrication of a robust fluidic platform built out of inert plastic materials and micromachined features that promote optimized convective fluid transport. The platform is tested for perfusion interrogation of rodent and human pancreatic islets, dynamic secretion of hormones, concomitant live-cell imaging, and optogenetic stimulation of genetically engineered islets. A coupled quantitative fluid dynamics computational model of glucose stimulated insulin secretion and fluid dynamics was first utilized to design device geometries that are optimal for complete perfusion of three-dimensional islets, effective collection of secreted insulin, and minimization of system volumes and associated delays.
View Article and Find Full Text PDFWe demonstrate a method for size based capture of viable circulating tumor cell (CTC) from whole blood, along with the release of these cells from chip for downstream analysis and/or culture. The strategy employs the use of a novel Parylene C membrane slot pore microfilter to capture CTC and a coating of poly (N-iso-propylacrylamide) (PIPAAm) for thermoresponsive viable release of the captured CTC. The capture of live cells is enabled by leveraging the design of a slot pore geometry with specific dimensions to reduce the shear stress typically associated with the filtration process.
View Article and Find Full Text PDFIn this study, biological cells are sensed and characterized with surface acoustic wave (SAW) devices utilising microcavities. After tumour cells in media are transported to and trapped in microcavities, the proposed platform uses SAW interaction between the substrate and the cells to extract their mechanical stiffness based on the ultrasound velocity. Finite element method (FEM) analysis and experimental results show that output phase information is an indicator of the stiffness modulus of the trapped cells.
View Article and Find Full Text PDFMetastasis is facilitated by cancer-associated fibroblasts (CAF) in the tumor microenvironment through mechanisms yet to be elucidated. In this study, we used a size-based microfilter technology developed by our group to examine whether circulating CAF identified by FAP and α-SMA co-expression (cCAF) could be distinguished in the peripheral blood of patients with metastatic breast cancer. In a pilot study of patients with breast cancer, we detected the presence of cCAFs in 30/34 (88%) patients with metastatic disease (MET group) and in 3/13 (23%) patients with localized breast cancer (LOC group) with long-term disease-free survival.
View Article and Find Full Text PDFStimulus responsive release of Circulating Tumor Cells (CTCs), with high recovery rates from their capture platform, is highly desirable for off-chip analyses. Here, we present a temperature responsive polymer coating method to achieve both release as well as culture of viable CTCs captured from patient blood samples.
View Article and Find Full Text PDFThe analysis of circulating tumour cells (CTCs) in cancer patients could provide important information for therapeutic management. Enrichment of viable CTCs could permit performance of functional analyses on CTCs to broaden understanding of metastatic disease. However, this has not been widely accomplished.
View Article and Find Full Text PDFCirculating tumor cells (CTCs) are recognized as a candidate biomarker with strong prognostic and predictive potential in metastatic disease. Filtration-based enrichment technologies have been used for CTC characterization, and our group has previously developed a membrane microfilter device that demonstrates efficacy in model systems and clinical blood samples. However, uneven filtration surfaces make the use of standard microscopic techniques a difficult task, limiting the performance of automated imaging using commercially available technologies.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
February 2013
Purpose: To examine the novel application of a commercially available optical coherence tomography (OCT) system toward molecular histopathology using gold nanorod (GNR) linked antibodies as a functionalized contrast agent to evaluate ocular surface squamous neoplasia (OSSN).
Methods: GNRs were synthesized and covalently attached to anti-glucose transporter-1 (GLUT-1) antibodies via carbodiimide chemistry. Three specimens from each of three distinct categories of human conjunctival tissue were selected for analysis, including conjunctiva without epithelial atypia (controls); conjunctival intraepithelial neoplasia, carcinoma in situ (CIS); and conjunctival squamous cell carcinoma (SCC).