This work presents the development and certification of the world's first certified reference material (CRM), BAM-S014, for a lithium nickel manganese cobalt oxide (LiNiMnCoO or Li-NMC 111) cathode material-an integral component in high-energy-density lithium-ion batteries that power electric vehicles (EVs), portable electronics, and stationary energy storage systems. By providing certified mass fractions for 11 elements, this CRM addresses a critical need for accurate and traceable elemental analysis, supporting quality control and regulatory compliance in the global battery industry. Ensuring reliable and harmonized measurements supports the efficient use of resources, including the reuse of recycled materials, and ultimately helps maintain product performance and safety.
View Article and Find Full Text PDFIn this study, we demonstrate the applicability of nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) for Ca, Fe, and Se quantification in human serum using isotope dilution (ID) analysis. The matrix tolerance of MICAP-MS in Na matrix was investigated, revealing that high Na levels can suppress the signal intensity. This suppression is likely due to the plasma loading and the space charge effect.
View Article and Find Full Text PDFThe statistical tool eCerto was developed for the evaluation of measurement data to assign property values and associated uncertainties of reference materials. The analysis is based on collaborative studies of expert laboratories and was implemented using the R software environment. Emphasis was put on comparability of eCerto with SoftCRM, a statistical tool based on the certification strategy of the former Community Bureau of Reference.
View Article and Find Full Text PDFBackground: The aim of our study was to analyze perioperative lactate levels and their predictive value for postoperative mortality and morbidity after liver resection.
Methods: The clinicopathological characteristics and outcomes of 152 patients who underwent liver resection for benign and malign diagnoses were analyzed retrospectively. Lactate concentrations at three different time points, (1) before liver resection (LAC-PRE), (2) after liver resection on day 0 (LAC-POST), and (3) on day one after the operation (LAC-POD1) were assessed regarding the prognostic value in predicting postoperative complications and mortality according to the Clavien-Dindo (CD) classification.
Lanthanide-based, spectrally shifting, and multi-color luminescent upconverting nanoparticles (UCNPs) have received much attention in the last decades because of their applicability as reporter for bioimaging, super-resolution microscopy, and sensing as well as barcoding and anti-counterfeiting tags. A prerequisite for the broad application of UCNPs in areas such as sensing and encoding are simple, robust, and easily upscalable synthesis protocols that yield large quantities of UCNPs with sizes of 20 nm or more with precisely controlled and tunable physicochemical properties from low-cost reagents with a high reproducibility. In this context, we studied the reproducibility, robustness, and upscalability of the synthesis of β-NaYF:Yb, Er UCNPs via thermal decomposition.
View Article and Find Full Text PDFFor more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2022
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer.
View Article and Find Full Text PDFAnal Bioanal Chem
September 2021
Zearalenone (ZEN), an estrogenic mycotoxin produced by several species of Fusarium fungi, is a common contaminant of cereal-based food worldwide. Due to frequent occurrences associated with high levels of ZEN, maize oil is a particular source of exposure. Although a European maximum level for ZEN in maize oil exists according to Commission Regulation (EC) No.
View Article and Find Full Text PDFHigh-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GF-MAS) was employed for determining adsorbable organic chlorine (AOCl) in water. Organic chlorine was indirectly quantified by monitoring the molecular absorption of the transient aluminum monochloride molecule (AlCl) around a wavelength of 261.42 nm in a graphite furnace.
View Article and Find Full Text PDFAn alternative method for lithium isotope amount ratio analysis based on a combination of high-resolution atomic absorption spectrometry and spectral data analysis by machine learning (ML) is proposed herein. It is based on the well-known isotope shift of approximately 15 pm for the electronic transition 2P←2S at around the wavelength of 670.8 nm, which can be measured by the state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry.
View Article and Find Full Text PDFObjective: Aim of our study was to test a noninvasive HSI technique as an intraoperative real time assessment tool for deceased donor kidney quality and function in human kidney allotransplantation.
Summary Of Background Data: HSI is capable to deliver quantitative diagnostic information about tissue pathology, morphology, and composition, based on the spectral characteristics of the investigated tissue. Because tools for objective intraoperative graft viability and performance assessment are lacking, we applied this novel technique to human kidney transplantation.
Since 1 January 2019 a maximum content of 0.6 mg kg cadmium (Cd) in cocoa powder sold to the final consumer or as an ingredient in sweetened cocoa powder sold to the final consumer (drinking chocolate) is set by the Commission Regulation (EU) No. 488/2014.
View Article and Find Full Text PDFThe objective of this work was to provide updated information on the development of the potential impact of heavy metal containing batteries on municipal waste and battery recycling processes following transposition of the new EU Batteries Directive 2006/66/EC. A representative sample of 146 different types of commercially available dry and button cells as well as lithium-ion accumulators for mobile phones were analysed for their mercury (Hg)-, cadmium (Cd)- and lead (Pb)-contents. The methods used for preparing the cells and analysing the heavy metals Hg, Cd, and Pb were either developed during a former study or newly developed.
View Article and Find Full Text PDFThe unique optical properties, such as size-tunable absorption and emission, caused semiconductor nanocrystals to attract a great deal of interest for recent technological developments. For the evaluation of semiconductor nanocrystals as new materials for various applications like optoelectronic devices, knowledge of the structure-property relationships is indispensable, but still presents a challenge. Here, we address these challenges for thioglycolic acid-capped CdTe nanocrystals with a focus on the quantification of thiol ligands, identification of the ligand shell structure and their influence on the optical properties of these nanocrystals.
View Article and Find Full Text PDFThe EU RoHS Directive (2002/95/EC of the European Parliament and of the Council) bans the placing of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants on the EU market. It necessitates methods for the evaluation of RoHS compliance of assembled electronic equipment. In this study mounted printed circuit boards from personal computers were analyzed on their content of the three elements Cd, Pb and Hg which were limited by the EU RoHS directive.
View Article and Find Full Text PDFThe objective of this work was to test the compliance of commercially available batteries with the German Battery Ordinance, a project of the German government that was initiated by the Federal Environment Agency. Different types of commercially available dry cells were analysed for their cadmium, lead and mercury contents. The dry cells underwent mechanical pre-treatment, separation of the different components and microwave-assisted digestion before determination of the heavy metals.
View Article and Find Full Text PDFWithin the framework of a German government project (initiated by the Federal Environment Agency) to check the compliance of commercially available batteries with the German Battery Ordinance concerning their heavy metal contents, 18 different types of commercially available zinc-air button cells were analysed for their cadmium, lead and mercury contents. After microwave assisted dissolution with aqua regia, Cd and Pb were determined using inductively coupled plasma mass spectrometry (ICP-MS), and Hg was determined using inductively coupled plasma optical emission spectrometry (ICP OES) and atomic absorption spectrometry. Cd contents were found to be much lower than the permitted limits; Pb contents were also found to be below the limits.
View Article and Find Full Text PDFThe mass fraction of potassium hydrogen phthalate (KHP) from a specific batch was certified as an acidimetric standard. Two different analytical methods on a metrological level were used to carry out certification analysis: precision constant current coulometric and volumetric titration with NaOH. It could be shown that with a commercial automatic titration system in combination with a reliable software for the end-point detection it is possible to produce equivalent results with the same accuracy in comparison to a definite method handled by a fundamental apparatus for traceable precision coulometry.
View Article and Find Full Text PDF