Publications by authors named "Satyavrata Samavedi"

Coamorphous mixtures (CAMs) prepared with two drugs have the potential to enhance the oral absorption of poorly soluble drugs and achieve combination therapy. From a practical standpoint, improving the glass transition temperature () of CAMs is desirable as it enhances stability and extends shelf life during storage. Toward the eventual goal of developing highly stable CAMs, this study establishes a generalized framework that systematically relates elevated values of CAMs to intermolecular interactions based on specific functional groups.

View Article and Find Full Text PDF

Chronic inflammation is a leading cause of neurodegeneration and vision loss in hyperglycemia-associated conditions such as diabetic retinopathy. Corticosteroid injections are widely used for treatment but suffer from limitations such as rapid drug clearance, short drug half-lives and frequent administration. While drug release from biomaterial carriers can overcome these shortcomings, evaluating the combined effects of corticosteroids and polymeric matrices under hyperglycemic stress is an important step towards aiding translation.

View Article and Find Full Text PDF

Electrospun fibrous meshes are widely used for tissue repair due to their ability to guide a host of cell responses including phenotypic differentiation and tissue maturation. A critical factor determining the eventual biological outcomes of mesh-based regeneration strategies is the early innate immune response following implantation. The natural healing process involves a sequence of tightly regulated, temporally varying and delicately balanced pro-/anti-inflammatory events which together promote mesh integration with host tissue.

View Article and Find Full Text PDF

Functionalization of electrospun meshes with growth factors (GFs) is a common strategy for guiding specific cell responses in tissue engineering. GFs can exert their intended biological effects only when they retain their bioactivity and can be subsequently delivered in a temporally controlled manner. However, adverse processing conditions encountered in electrospinning can potentially disrupt GFs and diminish their biological efficacy.

View Article and Find Full Text PDF

In this study, we offer new insights into the contrasting effects of electrospun fiber orientation on microglial polarization under normoxia and hypoxia, and establish for the first time, the intrinsically protective roles of electrospun meshes against hypoxia-induced microglial responses. First, resting microglia were cultured under normoxia on poly(caprolactone) fibers possessing two distinctly different fiber orientations. Matrix-guided differences in cell shape/orientation and differentially expressed Rho GTPases (RhoA, Rac1, Cdc42) were well-correlated with the randomly oriented fibers inducing a pro-inflammatory phenotype and the aligned fibers sustaining a resting phenotype.

View Article and Find Full Text PDF

Despite advances in the development of degradable polymers for drug delivery, effective translation of drug-loaded materials is often hindered due to a poor understanding of matrix property combinations that promote controlled and sustained release. In this study, we investigated the influence of dominant factors on the release of a hydrophobic glucocorticoid dexamethasone (DEX) from electrospun meshes. Polycaprolactone meshes released 98% of the drug within 24 h, while poly(l-lactide) meshes exhibited negligible release even after 28 days despite both polymers being slow-degrading.

View Article and Find Full Text PDF

The development of a minimally invasive, robust, and inexpensive technique that permits real-time monitoring of cell responses on biomaterial scaffolds can improve the eventual outcomes of scaffold-based tissue engineering strategies. Towards establishing correlations between in situ biological activity and cell fate, we have developed a comprehensive workflow for real-time volumetric imaging of spatiotemporally varying cytosolic calcium oscillations in pure microglial cells cultured on electrospun meshes. Live HMC3 cells on randomly oriented electrospun fibers were stained with a fluorescent dye and imaged using a laser scanning confocal microscope.

View Article and Find Full Text PDF

Synovium-derived mesenchymal stem cells (SMSCs) are an emerging cell source for regenerative medicine applications, including osteochondral defect (OCD) repair. However, in contrast to bone marrow MSCs, scaffold compositions which promote SMSC chondrogenesis/osteogenesis are still being identified. In the present manuscript, we examine poly(ethylene) glycol (PEG)-based scaffolds containing zonally-specific biochemical cues to guide SMSC osteochondral differentiation.

View Article and Find Full Text PDF

Bioactive coatings which support the adhesion of late-outgrowth peripheral blood endothelial progenitor cells (EOCs) are actively being investigated as a means to promote rapid endothelialization of "off-the-shelf," small-caliber arterial graft prostheses following implantation. In the present work, we evaluated the behavior of EOCs on thromboresistant graft coatings based on the collagen-mimetic protein Scl2-2 and poly(ethylene glycol) (PEG) diacrylate. Specifically, the attachment, proliferation, migration, and phenotype of EOCs on PEG-Scl2-2 hydrogels were evaluated as a function of Scl2-2 concentration (4, 8, and 12 mg/mL) relative to human umbilical vein endothelial cells (HUVECs).

View Article and Find Full Text PDF

The goal of the present study was to develop a fully three-dimensional (3D) coculture system that would allow for systematic evaluation of the interplay between activated macrophages (AMs) and chondrocytes in osteoarthritic disease progression and treatment. Toward this end, our coculture system was first validated against existing in vitro osteoarthritis models, which have generally cultured healthy normal chondrocytes (NCs)-in two-dimensional (2D) or 3D-with proinflammatory AMs in 2D. In this work, NCs and AMs were both encapsulated within poly(ethylene glycol) diacrylate hydrogels to mimic the native 3D environments of both cell types within the osteoarthritic joint.

View Article and Find Full Text PDF

Recently, a novel shape memory polymer foam based on the photopolymerization of poly(-caprolactone) diacrylate (PCLDA) has been developed. These PCLDA foams enter a temporary softened state when briefly treated with warm saline ( > of PCLDA), allowing them to conform to irregular bone defect "boundaries" prior to shape setting. When coated with a mechanically stable polydopamine (PD) layer, these PCLDA foams have previously been demonstrated to induce hydroxyapatite deposition.

View Article and Find Full Text PDF

This work evaluates the response of human aortic endothelial cells (HAECs) to thromboresistant collagen-mimetic hydrogel coatings toward improving the biocompatibility of existing "off-the-shelf" small-caliber vascular grafts. Specifically, bioactive hydrogels - previously shown to support α/α integrin-mediated cell adhesion but to resist platelet activation - were fabricated by combining poly(ethylene glycol) (PEG) with a 120 kDa, triple-helical collagen-mimetic protein(Scl2-2) containing the GFPGER adhesion sequence. Analysis of HAECs seeded onto the resulting PEG-Scl2-2 hydrogels demonstrated that HAEC adhesion increased with increasing Scl2-2 concentration, while HAEC migration rate decreased over this same concentration range.

View Article and Find Full Text PDF
Article Synopsis
  • PEGDA hydrogels are special materials used in biotechnology because they can be changed to have different strengths and properties.
  • Normally, the strength and size of these hydrogels are linked, making it hard to study them in detail for certain uses.
  • This research shows how adding different ingredients (called secondary reactive species) to PEGDA hydrogels can help create different strengths while keeping the size the same, allowing scientists to better explore their effects.
View Article and Find Full Text PDF

Although bone-patellar tendon-bone (B-PT-B) autografts are the gold standard for repair of anterior cruciate ligament ruptures, they suffer from drawbacks such as donor site morbidity and limited supply. Engineered tissues modeled after B-PT-B autografts are promising alternatives because they have the potential to regenerate connective tissue and facilitate osseointegration. Towards the long-term goal of regenerating ligaments and their bony insertions, the objective of this study was to construct 2D meshes and 3D cylindrical composite scaffolds - possessing simultaneous region-wise differences in fiber orientation, diameter, chemistry and mechanical properties - by electrospinning two different polymers from off-set spinnerets.

View Article and Find Full Text PDF

Calcium phosphate ceramics (CPCs) have been widely used as biomaterials for the regeneration of bone tissue because of their ability to induce osteoblastic differentiation in progenitor cells. Despite the progress made towards fabricating CPCs possessing a range of surface features and chemistries, the influence of material properties in orchestrating cellular events such as adhesion and differentiation is still poorly understood. Specifically, questions such as why certain CPCs may be more osteoinductive than others, and how material properties contribute to osteoinductivity/osteoconductivity remain unanswered.

View Article and Find Full Text PDF

Biomaterial scaffolds with gradients in architecture, mechanical and chemical properties have the potential to improve the osseointegration of ligament grafts by recapitulating phenotypic gradients that exist at the natural ligament-bone (L-B) interface. Towards the larger goal of regenerating the L-B interface, this in vitro study was performed to investigate the potential of two scaffolds with mineral gradients in promoting a spatial gradient of osteoblastic differentiation. Specifically, the first graded scaffold was fabricated by co-electrospinning two polymer solutions (one doped with nano-hydroxyapatite particles) from offset spinnerets, while the second was created by immersing the first scaffold in a 5 × simulated body fluid.

View Article and Find Full Text PDF

Current scaffolds for the regeneration of anterior cruciate ligament injuries are unable to capture intricate mechanical and chemical gradients present in the natural ligament-bone interface. As a result, stress concentrations can develop at the scaffold-bone interface, leading to poor osseointegration. Hence, scaffolds that possess appropriate mechano-chemical gradients would help establish normal loading properties at the interface, while promoting scaffold integration with bone.

View Article and Find Full Text PDF