Publications by authors named "Pascal Mercere"

The effect of adding Na and Mg metal ions on soft X-ray induced photochemistry (SXIP) is investigated. To that aim, the soft X-ray beam of the METROLOGIE beamline at the SOLEIL synchrotron was extracted through air to irradiate solutions circulating in a microfluidic cell. Benzoate was used as a sensitive profluorescent probe for hydroxyl radicals.

View Article and Find Full Text PDF

The development of efficient multilayer mirrors for the water window (a spectral region between absorption edges of carbon and oxygen, from 284 to 543 eV) remains a challenge. As the best candidate, the Cr/Sc multilayer provides maximum theoretical reflectivity of about 60% at near-normal incidence around the Sc L absorption edge (397 eV). However, the maximum measured peak reflectance published so far just slightly exceeds 20%.

View Article and Find Full Text PDF

Soft X-rays behave like particles with high linear energy transfer, as they deposit a large amount of their energy in the nanometric range, triggered by inner-shell ionization. In water, this can lead to the formation of a doubly ionized water molecule (HO) and the emission of two secondary electrons (photoelectron and Auger electron). Our focus lies on detecting and quantifying the superoxide (HO°) production via the direct pathway, i.

View Article and Find Full Text PDF

Synchrotron radiation can induce sample damage, whether intended or not. In the case of sensitive samples, such as biological ones, modifications can be significant. To understand and predict the effects due to exposure, it is necessary to know the ionizing radiation dose deposited in the sample.

View Article and Find Full Text PDF

The impressive progress in the performance of synchrotron radiation sources is nowadays driven by the so-called `ultimate storage ring' projects which promise an unprecedented improvement in brightness. Progress on the detector side has not always been at the same pace, especially as far as soft X-ray 2D detectors are concerned. While the most commonly used detectors are still based on microchannel plates or CCD technology, recent developments of CMOS (complementary metal oxide semiconductor)-type detectors will play an ever more important role as 2D detectors in the soft X-ray range.

View Article and Find Full Text PDF

The description of the biological effects of ionizing radiation requires a good knowledge of the dose deposition processes at both the cellular and molecular scales. However, experimental studies on the energy deposition specificity of sub-keV electrons, produced by most radiations, including high-energy photons and heavy ions, are scarce. Soft X-rays (0.

View Article and Find Full Text PDF

This paper presents the performance of a single-photon-counting hybrid pixel X-ray detector with synchrotron radiation. The camera was evaluated with respect to time-resolved experiments, namely pump-probe-probe experiments held at SOLEIL. The UFXC camera shows very good energy resolution of around 1.

View Article and Find Full Text PDF

The control protein Factor H (FH) is a crucial regulator of the innate immune complement system, where it is active on host cell membranes and in the fluid phase. Mutations impairing the binding capacity of FH lead to severe autoimmune diseases. Here, we studied the solution structure of full-length FH, in its free state and bound to the C3b complement protein.

View Article and Find Full Text PDF

An interferogram conditioning procedure, for subsequent phase retrieval by Fourier demodulation, is presented here as a fast iterative approach aiming at fulfilling the classical boundary conditions imposed by Fourier transform techniques. Interference fringe patterns with typical edge discontinuities were simulated in order to reveal the edge artifacts that classically appear in traditional Fourier analysis, and were consecutively used to demonstrate the correction efficiency of the proposed conditioning technique. Optimization of the algorithm parameters is also presented and discussed.

View Article and Find Full Text PDF

High-efficiency nanofocusing of hard X-rays using stacked multilevel Fresnel zone plates with a smallest zone width of 200 nm is demonstrated. The approach is to approximate the ideal parabolic lens profile with two-, three-, four- and six-level zone plates. By stacking binary and three-level zone plates with an additional binary zone plate, the number of levels in the optical transmission function was doubled, resulting in four- and six-level profiles, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • A new system called FLYSCAN allows for rapid multi-technique experiments by efficiently collecting and merging data from various detectors.
  • It enables microscopy data collection at a speed of milliseconds per pixel.
  • Initial experiments combining techniques like X-ray fluorescence and different imaging styles have been successfully conducted on biological and geological samples.
View Article and Find Full Text PDF

The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL.

View Article and Find Full Text PDF

We present in this Letter a type of quadriwave lateral shearing interferometer for x-ray phase imaging. This device is based on a phase chessboard, and we take advantage of the large spectrum of the source to produce interferograms with a propagation-invariant contrast. Such a grating has been created for hard x-ray interferometry and experimentally tested on a synchrotron beamline at Soleil.

View Article and Find Full Text PDF

The recent development of short-wavelength optics (X/EUV, synchrotrons) requires improved metrology techniques in terms of accuracy and curvature dynamic range. In this article a stitching Shack-Hartmann head dedicated to be mounted on translation stages for the characterization of X-ray mirrors is presented. The principle of the instrument is described and experimental results for an X-ray toroidal mirror are presented.

View Article and Find Full Text PDF

We present what we believe to be the first automatic alignment of a synchrotron beamline by the Hartmann technique. Experiments were performed, in the soft-x-ray range (E=3 keV, lambda=0.414 nm), by using a four-actuator Kirkpatrick-Baez (KB) active optic.

View Article and Find Full Text PDF

We report, for the first time to our knowledge, experimental demonstration of wave-front analysis via the Hartmann technique in the extreme ultraviolet range. The reference wave front needed to calibrate the sensor was generated by spatially filtering a focused undulator beam with 1.7- and 0.

View Article and Find Full Text PDF