Publications by authors named "Mark J Niebauer"

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to avoid complications related to transvenous implantable cardioverter-defibrillator (TV-ICD) leads. Device safety and efficacy were demonstrated previously with atypical clinical patients or limited follow-up.

Objectives: The S-ICD PAS (Subcutaneous Implantable Cardioverter-Defibrillator System Post Approval Study) is a real-world, multicenter, registry of U.

View Article and Find Full Text PDF

Objective: To test whether a high defibrillation threshold (DFT) marks patients with poor outcomes which are improved when DFT is decreased by system modification (subcutaneous coil implant; SM).

Background: The electrical substrate generating fast ventricular arrhythmias may generate poor outcomes among patients treated with implantable cardioverter-defibrillators (ICDs), even when arrhythmias are treated successfully. Since patients with high DFTs have increased mortality, we contrasted survival among patients with high DFT treated with and without SM.

View Article and Find Full Text PDF

Aims: Cryoballoon pulmonary vein isolation (PVI) is a safe and effective treatment for atrial fibrillation (AF). Current limitations include incomplete vein occlusion due to balloon rigidity and inconsistent electrogram recording, which impairs identification of isolation. We aimed to evaluate the acute safety and performance of a novel cryoballoon system.

View Article and Find Full Text PDF

Background: Cardiac resynchronization therapy (CRT) improves heart failure outcomes but has significant nonresponse rates, highlighting limitations in ECG selection criteria: QRS duration (QRSd) ≥150 ms and subjective labeling of left bundle branch block (LBBB). We explored unsupervised machine learning of ECG waveforms to identify CRT subgroups that may differentiate outcomes beyond QRSd and LBBB.

Methods: We retrospectively analyzed 946 CRT patients with conduction delay.

View Article and Find Full Text PDF

Background: Dofetilide is one of the only anti-arrhythmic agents approved for atrial fibrillation (AF) in patients with reduced left ventricular ejection fraction (LVEF). However, postapproval data and safety outcomes are limited. In this study, we assessed the incidence and predictors of LVEF improvement, safety, and outcomes in patients with AF with LVEF ≤35% without prior implantable cardioverter defibrillator, cardiac resynchronization therapy, or AF ablation.

View Article and Find Full Text PDF

Background: Patients with chronic renal disease on hemodialysis (HD) have limited vascular access and are at high risk of bacteremia. The subcutaneous implantable cardioverter-defibrillator (S-ICD) avoids vascular access, so it may be advantageous in this patient population.

Objective: The purpose of this study was to report outcomes of patients with end-stage renal disease enrolled in the multicenter S-ICD post-approval study (PAS).

View Article and Find Full Text PDF

Background: There is paucity of data regarding radiofrequency ablation for ventricular tachycardia (VT) in patients with cardiogenic shock and concomitant VT refractory to antiarrhythmic drugs on mechanical support.

Methods: Patients undergoing VT ablation at our center were enrolled in a prospectively maintained registry and screened for the current study (2010-2017).

Results: All 21 consecutive patients with cardiogenic shock and concomitant refractory ventricular arrhythmia undergoing bailout ablation due to inability to wean off mechanical support were included.

View Article and Find Full Text PDF

Background: Injury to the cardiac venous structures can complicate left ventricular lead placement for cardiac resynchronization therapy (CRT). Little is known about the outcomes of coronary sinus (CS) dissection with or without perforation.

Objective: The purpose of this study was to determine the outcomes in patients who had a CS injury during CRT implantation.

View Article and Find Full Text PDF

Background: Cardiac resynchronization therapy (CRT) has significant nonresponse rates. We assessed whether machine learning (ML) could predict CRT response beyond current guidelines.

Methods: We analyzed CRT patients from Cleveland Clinic and Johns Hopkins.

View Article and Find Full Text PDF

Background: Although dofetilide labeling states that the drug must be initiated or reinitiated with continuous electrocardiographic monitoring and in the presence of trained personnel, the risks of dofetilide reloading justifying repeat hospitalization have not been investigated.

Methods And Results: Patients admitted for dofetilide reloading for atrial arrhythmias were retrospectively reviewed. The need for dose adjustment and the incidence of torsades de pointes (TdP) were identified.

View Article and Find Full Text PDF

Introduction: QRS characteristics are the cornerstone of patient selection in cardiac resynchronization therapy (CRT) and the presence of left bundle branch block (LBBB) and baseline QRS ≥150 milliseconds portends a good outcome. We previously showed that baseline QRS frequency analysis adds predictive value to LBBB alone and have hypothesized that a change in frequency characteristics following CRT may produce additional predictive value.

Methods: We examined the QRS frequency characteristics of 182 LBBB patients before and soon after CRT.

View Article and Find Full Text PDF

Background: Baseline QRS duration (QRSd) ≥150 ms is a recognized predictor of clinical improvement by cardiac resynchronization therapy (CRT), particularly for those with left bundle branch (LBBB). Patients with QRSd <150 ms are considered less likely to respond.

Objective: The purpose of this study was to test our theory that left ventricular dyssynchrony, although usually associated with wider QRSd, also exhibits lower QRS frequency characteristics and that low-frequency content predicts CRT response in LBBB patients.

View Article and Find Full Text PDF

Background: Despite sparse clinical data, current atrial fibrillation (AF) guidelines favor amiodarone as a drug of choice for patients with left ventricular hypertrophy (LVH).

Objective: This study tested the hypothesis that patients with persistent AF and LVH on nonamiodarone antiarrhythmics have higher mortality compared to patients on amiodarone.

Methods: In an observational cohort analysis of patients who underwent cardioversion for AF, patients with LVH, defined as left ventricular wall thickness ≥1.

View Article and Find Full Text PDF

Background: It is difficult to predict adverse patient outcomes associated with transvenous lead extraction (TLE) procedures.

Objective: The purpose of this study was to examine the safety and efficacy of chronic endovascular pacemaker and implantable cardioverter-defibrillator (ICD) lead extraction and risk factors associated with adverse patient outcomes.

Methods: Consecutive patients undergoing TLE at the Cleveland Clinic between August 1996 and August 2011 were included in the analysis.

View Article and Find Full Text PDF

Background: Comparative safety and efficacy associated with transvenous lead extraction (TLE) of recalled and non-recalled implantable cardioverter-defibrillator (ICD) leads has not been well characterized.

Objectives: To compare the indications, techniques, and procedural outcomes of recalled vs non-recalled ICD lead extraction procedures.

Methods: TLE procedures performed at our institution from June 2002 to June 2012 in which Riata, Sprint Fidelis, or non-recalled ICD leads were extracted were included in the analysis.

View Article and Find Full Text PDF

Aims: Cryoballoon ablation is an emerging therapy for atrial fibrillation (AF). However, the Arctic Front cryoballoon (Medtronic) cannot be localized on current electroanatomic mapping (EAM) systems. We describe a technique to visualize guidewires in an impedance-based EAM system.

View Article and Find Full Text PDF

Background: A significant proportion of implantable cardioverter-defibrillators (ICDs) have been subject to Food and Drug Administration (FDA) advisories. The impact of device advisories on mortality or patient care is poorly understood. Although estimated risks of ICD generators under advisory are low, dependency on ICD therapies to prevent sudden death justifies the assessment of long-term mortality.

View Article and Find Full Text PDF

Patients with non-left bundle branch block (LBBB) morphologies are thought to derive less benefit from cardiac resynchronization therapy (CRT) than those with LBBB. However, some patients do exhibit improvement. The characteristics associated with a response to CRT in patients with non-LBBB morphologies are unknown.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to determine patient compliance and effectiveness of antiarrhythmic treatment by the wearable cardioverter-defibrillator (WCD).

Background: Effectiveness of the WCD for prevention of sudden death is dependent on event type, patient compliance, and appropriate management of ventricular tachycardia/ventricular fibrillation (VT/VF).

Methods: Compliance and events were recorded in a nationwide registry of post-market release WCDs.

View Article and Find Full Text PDF

Background: Expanded polytetrafluoroethylene (ePTFE) coated and medical adhesive back-filled (MABF) implantable cardioverter-defibrillator (ICD) coils have been promoted to reduce the fibrous ingrowth into coils that can complicate lead extraction.

Objective: The purpose of this study was to test the hypothesis that ePTFE or MABF coatings are associated with greater ease of extraction.

Methods: Consecutive isolated ICD lead extraction cases were identified from a prospectively collected clinical database.

View Article and Find Full Text PDF

Background: The RLB waveform has been shown to be superior in overall efficacy to the MDS waveform for cardioversion of AF in one prospective study and one large retrospective analysis. However, little is known about the efficacy of the RLB waveform at lower energies.

Objective: This study was undertaken to define the cardioversion thresholds for atrial fibrillation (AF) and flutter (FL) using the rectilinear biphasic (RLB) waveform and compare these to the cardioversion threshold using the conventional monophasic damped sine (MDS) waveform.

View Article and Find Full Text PDF

External cardioversion using the monophasic damped sine (MDS) waveform is successful 70% to 94% of the time when using up to 360 J. The rectilinear biphasic (RLB) defibrillator has been shown to be superior in efficacy to the MDS waveform in atrial cardioversion in a small randomized study. This larger, retrospective study compares the results of the RLB waveform with those of the MDS waveform for cardioversion of atrial fibrillation (AF) and atrial flutter in a large cohort of patients.

View Article and Find Full Text PDF

This study tested the hypothesis that prolonged QRS duration independently predicts long-term mortality in patients who underwent risk stratification and treatment for ventricular arrhythmias. Patients who underwent risk stratification by electrophysiologic study were identified. Electrophysiologic study results were defined as positive if sustained monomorphic ventricular tachycardia was induced.

View Article and Find Full Text PDF

Extraction of pacemaker leads has been demonstrated to be successful and safe in experienced hands using current tools. Whether application of such techniques and tools yield similar results among patients undergoing extraction of nonthoracotomy implantable defibrillator leads is unknown. This report describes a retrospective analysis of indications, techniques used, and outcome of patients who had a single ventricular nonthoracotomy implantable defibrillator lead extracted at The Cleveland Clinic Foundation.

View Article and Find Full Text PDF