Publications by authors named "Marc B Muijzer"

Topic: The goal of this systematic review was to evaluate the measurement variability of distance visual acuity (VA) and refractive error (RE).

Clinical Relevance: Accurately measuring VA and RE is fundamental to eye care; however, no scientific consensus has been reached on the measurement variability. Scientific literature suggests limits of variability of ±0.

View Article and Find Full Text PDF

The intraoperative optical coherence tomography (iOCT) is recently introduced in Descemet membrane endothelial keratoplasty (DMEK) surgery, which aims to increase clinical performance and surgery safety. However, the acquisition of this modality is a substantial investment. The objective of this paper is to report on the cost-effectiveness of an iOCT-protocol in DMEK surgery with the Advanced Visualization in Corneal Surgery Evaluation (ADVISE) trial.

View Article and Find Full Text PDF

Purpose: The aim of this study was to explore video-graded intraoperative risk factors for graft detachment (GD) and rebubbling in Descemet membrane endothelial keratoplasty surgery.

Methods: A post hoc analysis of 65 eyes of 65 pseudophakic subjects with Fuchs endothelial dystrophy that underwent Descemet membrane endothelial keratoplasty surgery as part of the Advanced Visualization In Corneal Surgery Evaluation trial. All surgical recordings were assessed by 2 graders using a structured assessment form.

View Article and Find Full Text PDF

Objective: To evaluate if an intraoperative-OCT (iOCT) optimized surgical protocol without prolonged overpressure is non-inferior to a standard protocol during Descemet membrane endothelial keratoplasty (DMEK).

Methods: Sixty-five pseudophakic eyes of 65 patients with Fuchs endothelial dystrophy scheduled for routine DMEK were recruited in this prospective non-inferiority international multicenter randomized control trial. Subjects were randomized to the control arm (n=33) without iOCT-use and raising the intraocular pressure above normal physiological limits for 8 minutes (i.

View Article and Find Full Text PDF

Correct Descemet Membrane Endothelial Keratoplasty (DMEK) graft orientation is imperative for success of DMEK surgery, but intraoperative evaluation can be challenging. We present a method for automatic evaluation of the graft orientation in intraoperative optical coherence tomography (iOCT), exploiting the natural rolling behavior of the graft. The method encompasses a deep learning model for graft segmentation, post-processing to obtain a smooth line representation, and curvature calculations to determine graft orientation.

View Article and Find Full Text PDF

This study aimed to describe the surgical challenges, management, and value of intraoperative optical coherence tomography in a case of a bilateral Descemet Stripping Automated Endothelial Keratoplasty corneal transplantation at 17 weeks of age for the treatment of severe posterior polymorphous corneal dystrophy resulting from a de novo mutation of the OVOL2-gene.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the predictive value of pachymetry mapping 1 day after Descemet membrane endothelial keratoplasty (DMEK) as a biomarker for early graft detachment.

Methods: This was a post hoc analysis of 65 pseudophakic subjects with Fuchs endothelial dystrophy who underwent DMEK surgery between December 2018 and April 2021 as part of the Advanced Visualization In Corneal Surgery Evaluation international multicenter randomized controlled trial. One eye per patient was included.

View Article and Find Full Text PDF

Purpose: To evaluate the outcome of a web-based digital assessment of visual acuity and refractive error, compared to a conventional supervised assessment, in keratoconus patients with complex refractive errors.

Material And Methods: Keratoconus patients, aged 18 to 40, with a refractive error between -6 and +4 diopters were considered eligible. An uncorrected visual acuity and an assessment of refractive error was taken web-based (index test) and by manifest refraction (reference test) by an optometrist.

View Article and Find Full Text PDF

In this systematic review, we provide an overview of the current state of intraoperative optical coherence tomography (iOCT). As iOCT technology is increasingly utilized, its current clinical applications and potential uses warrant attention. Here, we categorize the findings of various studies by their respective fields, including the use of iOCT in vitreoretinal surgery, corneal surgery, glaucoma surgery, cataract surgery, and pediatric ophthalmology.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical value of intraoperative optical coherence tomography (iOCT) and prolonged overpressure in Descemet membrane endothelial keratoplasty for surgical safety, efficiency, and outcome.

Methods: All Descemet membrane endothelial keratoplasties performed by the same surgeon from November 2016 through April 2018 at the University Medical Center Utrecht were included, including 6 months of follow-up. The primary outcome was the prevalence of adverse events, and the secondary outcomes included critical decision-making and surgery time.

View Article and Find Full Text PDF

Background: Digital tools provide a unique opportunity to increase access to eye care. We developed a Web-based test that measures visual acuity and both spherical and cylindrical refractive errors. This test is Conformité Européenne marked and available on the Easee website.

View Article and Find Full Text PDF

Importance: Defining keratoconus progression is fundamental in clinical decision making because crosslinking treatments are indicated when the disease is considered progressive. Currently, there is no consensus which parameters should be used to define progression.

Objective: To assess and validate a novel clinical scoring system as an easy-to-use assessment tool for crosslinking treatment in patients with keratoconus.

View Article and Find Full Text PDF

Purpose: Posterior lamellar corneal surgery is considered the standard of care for irreversible endothelial cell dysfunction. Pre-cut grafts can be prepared either manually (Descemet stripping endothelial keratoplasty; DSEK) or mechanically (Descemet stripping automated endothelial keratoplasty; DSAEK). We performed a head-to-head clinical comparison between DSEK and DSAEK grafts.

View Article and Find Full Text PDF

Purpose: To compare visual performance using autorefraction and manifest refraction assessments in patients with keratoconus and investigate whether autorefraction measurements lead to suboptimal visual performance.

Methods: Corrected distance visual acuity (CDVA) was measured in 90 eyes of 61 patients with keratoconus with both autorefraction and manifest refraction, in a random order. Maximum keratometry (Kmax), cone location, and wavefront aberration were determined with Scheimpflug tomography.

View Article and Find Full Text PDF