REC Interv Cardiol
February 2025
Introduction And Objectives: Transcatheter aortic valve implantation (TAVI) for pure aortic regurgitation is challenging due to inadequate device anchoring and increased risks of device embolization and paravalvular regurgitation (PVR). This study aimed to review the safety and efficacy of TAVI for aortic regurgitation with devices specifically designed for this indication.
Methods: A comprehensive search of PubMed, Web of Science, Cochrane Library, and major conference archives up to April 2024 identified 143 unique results based on predefined criteria.
Transcatheter aortic valve implantation (TAVI) has become a first-line management option across all risk categories of elderly patients with symptomatic severe aortic stenosis. As the indications of TAVI expand, the age and the surgical risk of patients who undergo TAVI is decreasing making lifetime management after TAVI more compelling. After TAVI, patients endure an incremental risk of acute coronary syndromes, which have unique mechanisms and management challenges that are yet to be fully understood.
View Article and Find Full Text PDFPatients who undergo percutaneous coronary intervention (PCI) to the left main (LM) coronary artery in the setting of acute coronary syndrome (ACS) were not adequately studied in the era of modern PCI. We investigated early and long-term outcomes of these patients, especially those with a true LM bifurcation stenosis. The Left Main Intervention in Acute Coronary Syndrome (LIMACS) is a multicenter registry that enrolled patients who underwent PCI to unprotected LM disease in the setting of ACS using a drug-eluting stent.
View Article and Find Full Text PDFWe show that numerical linked cluster expansions (NLCEs) based on sufficiently large building blocks allow one to obtain accurate low-temperature results for the thermodynamic properties of spin lattice models with continuous disorder distributions. Specifically, we show that such results can be obtained computing the disorder averages in the NLCE clusters before calculating their weights. We provide a proof of concept using three different NLCEs based on L, square, and rectangle building blocks.
View Article and Find Full Text PDFBackground: The prevalence of secondary tricuspid regurgitation (TR) increases with ageing, but the exact mechanisms and the pattern of tricuspid valve (TV) remodelling are yet to be defined. This knowledge is needed to guide patient selection for the evolving therapeutic options. We sought to explore the prevalence and predictors of secondary TR in the elderly, as well as the associated pattern of right-heart chamber and TV remodelling.
View Article and Find Full Text PDFBackground: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice.
Aim: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV.
We introduce a numerical linked cluster expansion for square-lattice models whose building block is an L-shape cluster. For the spin-1/2 models studied in this work, we find that this expansion exhibits a similar or better convergence of the bare sums than that of the (larger) square-shaped clusters and can be used with resummation techniques (like the site- and bond-based expansions) to obtain results at even lower temperatures. We compare the performance of weak- and strong-embedding versions of this expansion in various spin-1/2 models and show that the strong-embedding version is preferable because of its convergence properties and lower computational cost.
View Article and Find Full Text PDFBackground: Estimation of regurgitant fraction by videodensitometry (VD-AR) of aortic root angiograms is a new tool for objective grading of paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI). Stratification with boundaries at 6% and 17% has been proposed to reflect "none/trace", "mild" and "moderate or higher" PVR.
Objective: We sought to investigate the association of strata of VD-AR with 3-year mortality and to compare VD-AR with visual grading of angiograms.
Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models.
View Article and Find Full Text PDF(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included.
View Article and Find Full Text PDFBackground: The balloon expandable Myval transcatheter heart valve (THV) showed encouraging results regarding residual aortic regurgitation (AR) from multiple observational studies. The newly designed Myval Octacor has been introduced recently, aiming for a reduction in AR and improved performance.
Objectives: The focus of this study is to report the incidence of AR using the validated quantitative Videodensitometry angiography technology (qLVOT-AR%) in the first in human use of the Myval Octacor THV system.
Background: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges.
View Article and Find Full Text PDFBackground: This paper looks to validate the risk score from the Heart Failure Association of the European Society of Cardiology and the International Cardio-Oncology Society (HFA-ICOS) for predicting potential cardiotoxicity from anticancer therapy for patients positive for human epidermal growth factor receptor 2.
Methods: A total of 507 patients with at least five years since index diagnosis of breast cancer were retrospectively divided according to the HFA-ICOS risk proforma. According to level of risk, these groups were assessed for rates of cardiotoxicity via mixed-effect Bayesian logistic regression model.
Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone.
View Article and Find Full Text PDF(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE .
View Article and Find Full Text PDFLeft ventricular assist device (LVAD) therapy has been instrumental in saving lives of patients with end-stage heart failure (HF). Recent generation devices have short-to-mid-term survival rates close to heart transplantation. Unfortunately, up to 1 in 4 patients develop a life-threatening right-sided HF (RHF) early post LVAD implantation, with high morbidity and mortality rate, necessitating prolonged ICU stay, prolonged inotropic support, and implantation of a right-ventricular assist device.
View Article and Find Full Text PDFJ Soc Cardiovasc Angiogr Interv
April 2022
Background: Aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is a major predictor of short- and long-term survival. Thus far, no independent quantitative comparison of AR among commercially available transcatheter heart valves (THVs) has been performed.
Objectives: We sought to assess and compare the degree of acute AR following TAVR between 11 commercially available THVs and update our previous multicenter, pooled analysis.
Cancer-therapy related cardiotoxicity (CTRCT) is a significant and frequent complication of monoclonal antibody directed therapy, especially Trastuzumab, for human epidermal growth factor receptor 2 (HER2) overexpressing breast cancers. Reliable, clinically available molecular predictive markers of CTRCT have not yet been developed. Identifying specific genetic variants and their molecular markers, which make the host susceptible to this complication is key to personalised risk stratification.
View Article and Find Full Text PDFPesticides are indispensably essential in agricultural practices. Traditional pesticides and environmentally friendly pesticides both are used to control the damage caused by pests and diseases. Conventional procedures were carried out to detect pesticide residues using chromatography and spectrophotometric techniques.
View Article and Find Full Text PDFAcute right-sided heart failure (RHF) is a complex clinical syndrome, with a wide range of clinical presentations, associated with increased mortality and morbidity, but about which there is a scarcity of evidence-based literature. A temporary right-ventricular assist device (t-RVAD) is a potential treatment option for selected patients with severe right-ventricular dysfunction as a bridge-to-recovery or as a permanent solution. We sought to conduct a systematic review to determine the safety and efficacy of t-RVAD implantation.
View Article and Find Full Text PDFBicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations.
View Article and Find Full Text PDFThe new-generation ACURATE 2 system was commercially released in September 2020. In this study, we sought to compare the aortic regurgitation (AR) severity of the ACURATE 2 versus the ACURATE transcatheter heart valve, using quantitative videodensitometric angiography (qAR). This is a retrospective, Corelab analysis of final post-transcatheter aortic valve implantation (TAVI) aortograms of patients treated with the ACURATE 2 and ACURATE systems.
View Article and Find Full Text PDFObjectives: We aimed to compare the quantitative angiographic aortic regurgitation (AR) into the left ventricular out flow tract (LVOT-AR) of five different types of transcatheter self-expanding valves and to investigate the impact of the learning curve on post-TAVR AR.
Background: Quantitative video densitometric aortography is an objective, accurate, and reproducible tool for assessment of AR following TAVR.
Methods And Results: This retrospective academic core-lab analysis, analyzed 1150 consecutive cine aortograms performed immediately post-TAVR.
Purpose: Postoperative cholelithiasis (CL) is a latent complication of bariatric surgery. The aim of this study was to evaluate the role of ursodeoxycholic acid (UDCA) in the prevention of CL after laparoscopic sleeve gastrectomy (LSG).
Methods: This was a retrospective analysis of the prospectively collected data of patients with morbid obesity who underwent LSG.