Objectives: The breast ultrasound trial (BUST) demonstrates a high negative predictive value of ultrasound for women presenting with focal breast complaints, suggesting a potential shift from mammography/digital breast tomosynthesis (DBT) to ultrasound as a primary imaging modality. This BUST side-study explored women's perspectives on adopting ultrasound as the primary diagnostic tool.
Methods: Twenty-nine female BUST participants (mean age = 48.
Background: Although DBT is the standard initial imaging modality for women with focal breast symptoms, the importance of ultrasound has grown rapidly in the past decades. Therefore, the Breast UltraSound Trial (BUST) focused on assessing the diagnostic value of ultrasound and digital breast tomosynthesis (DBT) for the evaluation of breast symptoms by reversing the order of breast imaging; first performing ultrasound followed by DBT. This side-study of the BUST evaluates patients' perceptions of ultrasound and DBT in a reversed setting.
View Article and Find Full Text PDFOwing to its high sensitivity, as concluded in the Breast UltraSound Trial (BUST), targeted ultrasound (US) now seems a promising accurate stand-alone modality for diagnostic evaluation of breast complaints. This approach implies omission of bilateral digital breast tomosynthesis (DBT) in women with clearly benign US findings. Within BUST, radiologists started with US followed by DBT.
View Article and Find Full Text PDFObjectives: To assess the diagnostic performance of 3D automated breast ultrasound (3D-ABUS) in breast cancer screening in a clinical setting.
Materials And Methods: All patients who had 3D-ABUS between January 2014 and January 2022 for screening were included in this retrospective study. The images were reported by 1 of 6 breast radiologists based on the Breast Imaging Reporting and Data Systems (BI-RADS).
Objectives: This project aims to model an optimal scanning environment for breast magnetic resonance imaging (MRI) screening based on real-life data to identify to what extent the logistics of breast MRI can be optimized.
Materials And Methods: A novel concept for a breast MRI screening facility was developed considering layout of the building, workflow steps, used resources, and MRI protocols. The envisioned screening facility is person centered and aims for an efficient workflow-oriented design.
Background Digital breast tomosynthesis (DBT) followed by targeted US is commonly performed to evaluate women with localized breast complaints. However, the added value of DBT in addition to targeted US is unknown. Omitting DBT may be cost-effective and improve patient comfort but may miss potential breast cancer.
View Article and Find Full Text PDFNPJ Breast Cancer
March 2023
Accurately determining the molecular subtypes of breast cancer is important for the prognosis of breast cancer patients and can guide treatment selection. In this study, we develop a deep learning-based model for predicting the molecular subtypes of breast cancer directly from the diagnostic mammography and ultrasound images. Multi-modal deep learning with intra- and inter-modality attention modules (MDL-IIA) is proposed to extract important relations between mammography and ultrasound for this task.
View Article and Find Full Text PDFThe high diagnostic performance of modern breast ultrasound (US) opens the possibility to shift toward targeted US as initial imaging test in women with breast complaints. This comparative cohort study investigates the effects of starting with US followed by digital breast tomosynthesis (DBT), as practiced in the breast ultrasound study (BUST), on women's health-related quality of life (QoL). Fifty BUST participants and 50 "controls" who underwent DBT and US in regular order filled out the EQ-5D-3L three times during their visit: BUST participants before US (T1), after US (T2), and after DBT (T3) and non-BUST participants before DBT (T1), after DBT (T2), and after US (T3).
View Article and Find Full Text PDFPurpose: In this study, we compare readout-segmented echo-planar imaging (rs-EPI) Diffusion Weighted Imaging (DWI) to a work-in-progress single-shot EPI with modified Inversion Recovery Background Suppression (ss-EPI-mIRBS) sequence at 3 T using a b-value of 2000 s/mm on image quality, lesion visibility and evaluation time.
Method: From September 2017 to December 2018, 23 women (one case used for training) with known breast cancer were included in this study, after providing signed informed consent. Women were scanned with the conventional rs-EPI sequence and the work-in-progress ss-EPI-mIRBS during the same examination.
Objectives: Digital breast tomosynthesis (DBT) increases sensitivity of mammography and is increasingly implemented in breast cancer screening. However, the large volume of images increases the risk of reading errors and reading time. This study aims to investigate whether the accuracy of breast radiologists reading wide-angle DBT increases with the aid of an artificial intelligence (AI) support system.
View Article and Find Full Text PDFPurpose: To compare diffusion-weighted imaging of the breast performed with a conventional readout-segmented echo-planar imaging (rs-EPI) sequence to when using a prototype simultaneous multi-slice single-shot EPI (SMS-ss-EPI) acquisition.
Method: From September 2017 to December 2018, 26 women with histologically proven breast cancer were scanned with the conventional rs-EPI and the SMS-ss-EPI at 3 T during the same imaging examination. Four breast radiologists (4-13 years of experience) independently scored both acquired series of 25 women (one case was used for training) for overall image quality (1: extremely poor to 9: excellent) and artifacts (1: very disturbing to 5: not present).
Objective: Ultrafast dynamic contrast-enhanced magnetic resonance imaging of the breast enables assessment of the contrast inflow dynamics while providing images with diagnostic spatial resolution. However, the slice thickness of common ultrafast techniques still prevents multiplanar reconstruction. In addition, some temporal blurring of the enhancement characteristics occurs in case view-sharing is used.
View Article and Find Full Text PDF