Publications by authors named "Flurin Pfiffner"

Introduction: Otosclerosis is a known cause of particularly conductive hearing loss of a variable extent. Radiological examination reveals footplate thickening in addition to heterogeneously distributed hypodense foci. The objective of this study was to investigate the correlation between a thickened stapes footplate and its association with perioperative audiometric findings and postoperative complications.

View Article and Find Full Text PDF

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

The brainstem auditory-evoked response (BAER) is an established electrophysiological measure of neural activity from the auditory nerve up to the brain stem. The BAER is used to diagnose abnormalities in auditory pathways and in neurophysiological human and animal research. However, normative data for BAERs in sheep, which represent an adequate large animal model for translational and basic otological research, are lacking.

View Article and Find Full Text PDF

Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches.

Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system.

View Article and Find Full Text PDF

Objectives: The inter-phase gap (IPG) offset effect is defined as the dB offset between the linear parts of electrically evoked compound action potential (ECAP) amplitude growth functions for two stimuli differing only in IPG. The method was recently suggested to represent neural health in cochlear implant (CI) users while being unaffected by CI electrode impedances. Hereby, a larger IPG offset effect should reflect better neural health.

View Article and Find Full Text PDF

Various representations exist in the literature to visualize electrocochleography (ECochG) recordings along the basilar membrane (BM). This lack of generalization complicates comparisons within and between cochlear implant (CI) users, as well as between publications. This study synthesized the visual representations available in the literature via a systematic review and provides a novel approach to visualize ECochG data in CI users.

View Article and Find Full Text PDF

Introduction: The mechanism of non-osseous bone conduction pathways, involving the intracranial contents (ICC) of the skull, is still not well understood. This study aimed to investigate the influence of the ICC on the skull bone wave propagation, including dependence on stimulation location and coupling.

Methods: Three Thiel-embalmed whole-head cadaver specimens were studied before and after the removal of the ICC.

View Article and Find Full Text PDF

The objective to preserve residual hearing during cochlear implantation has recently led to the use of intracochlear electrocochleography (ECochG) as an intraoperative monitoring tool. Currently, a decrease in the amplitude of the difference between responses to alternating-polarity stimuli (DIF response), predominantly reflecting the hair cell response, is used for providing feedback. Including other ECochG response components, such as phase changes and harmonic distortions, could improve the accuracy of surgical feedback.

View Article and Find Full Text PDF

Background: Under bone conduction (BC) stimulation, the otic capsule, and surrounding temporal bone, undergoes a complex 3-dimentional (3D) motion that depends on the frequency, location and coupling of the stimulation. The correlation between the resultant intracochlear pressure difference across the cochlear partition and the 3D motion of the otic capsule is not yet known and is to be investigated.

Methods: Experiments were conducted in 3 fresh frozen cadaver heads, individually on each temporal bone, resulting in a total of 6 samples.

View Article and Find Full Text PDF

ADHEAR is a bone conduction hearing aid that uses an adhesive skin adapter. In the current study, the use of ADHEAR as an audiometric bone stimulator was investigated in normal-hearing subjects by comparing it to the standard Radio-Ear B71. Bone conduction thresholds of 15 normal-hearing subjects (aged 21-36 years) were measured four times in a randomized order, twice with the B71 and twice with the ADHEAR.

View Article and Find Full Text PDF

To assess the incidence and severity of changes in hearing threshold in patients undergoing high-dose pencil-beam-scanning proton therapy (PBS-PT). This retrospective cohort study included fifty-one patients (median 50 years (range, 13-68)) treated with PBS-PT for skull base tumors. No chemotherapy was delivered.

View Article and Find Full Text PDF

Background: The frequency dependent contributions of the various bone conduction pathways are poorly understood, especially the fluid pathway. The aim of this work is to measure and investigate sound pressure propagation from the intracranial space to the cochlear fluid.

Methods: Stimulation was provided sequentially to the bone (BC) or directly to the intracranial contents (hydrodynamic conduction, or HC) in four cadaver heads, where each ear was tested individually, for a total of 8 samples.

View Article and Find Full Text PDF

Background: To evaluate the long-term audiological outcomes combined with the Hearing Implant Sound Quality Index (HISQUI) after Vibrant Soundbridge (VSB) implantation.

Methods: Prospective recall cohort study of patients who received a VSB in a tertiary academic medical center between 1996 and 2017. Air conduction (AC) and bone conduction (BC), sound field thresholds in aided and unaided conditions, and speech discrimination in noise (Oldenburger sentence test) were measured.

View Article and Find Full Text PDF

This study is aimed at the quantitative investigation of wave propagation through the skull bone and its dependence on different coupling methods of the bone conduction hearing aid (BCHA). Experiments were conducted on five Thiel embalmed whole head cadaver specimens. An electromagnetic actuator from a commercial BCHA was mounted on a 5-Newton steel headband, at the mastoid, on a percutaneously implanted screw (Baha Connect), and transcutaneously with a Baha Attract (Cochlear Limited, Sydney, Australia), at the clinical bone anchored hearing aid (BAHA) location.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochlea's inner wall (the modiolus) and electrical impedance measurements made at the CI's electrode contacts. We introduced a protocol for "three-point impedances" in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion.

View Article and Find Full Text PDF

Micro-Electro-Mechanical Systems (MEMS) acoustic transducers are highly sophisticated devices with high sensing performance, small size, and low power consumption. To be applied in an implantable medical device, they require a customized packaging solution with a protecting shell, usually made from titanium (Ti), to fulfill biocompatibility and hermeticity requirements. To allow acoustic sound to be transferred between the surroundings and the hermetically sealed MEMS transducer, a compliant diaphragm element needs to be integrated into the protecting enclosure.

View Article and Find Full Text PDF

Objective: To assess the prevalence and implications of phase changes in extracochlear electrocochleography (ECochG) recordings during cochlear implantation.

Materials And Methods: Extracochlear ECochG recordings were performed before and after insertion of the cochlear implant (CI) electrode by a recording electrode placed on the promontory. Acoustic stimuli were tone bursts at 250, 500, 750, and 1,000 Hz.

View Article and Find Full Text PDF

A retrospective analysis to quantify age-related changes of the incudo-malleolar joint (IMJ) and incudo-stapedial joint (ISJ), and to analyse changes in the air-bone gap (ABG) with age, was performed. Defined histologic parameters of 153 IMJ and 106 ISJ from subjects aged from birth to 70 years were correlated to age. Additionally, audiograms of 1760 ears of 974 other subjects aged 20 to 80 years were retrospectively analysed and the ABG was correlated to age.

View Article and Find Full Text PDF

The use of electrocochleography (ECochG) for providing real-time feedback of cochlear function during cochlear implantation is receiving increased attention for preventing cochlear trauma and preserving residual hearing. Although various studies investigated the relationship between intra-operative ECochG measurements and surgical outcomes in recent years, the limited interpretability of ECochG response changes leads to conflicting study results and prevents the adoption of this method for clinical use. Specifically, the movement of the recording electrode with respect to the different signal generators in intracochlear recordings makes the interpretation of signal changes with respect to cochlear trauma difficult.

View Article and Find Full Text PDF

The reliable prediction of cochlear implant (CI) speech perception outcomes is highly relevant and can facilitate the monitoring of postoperative hearing performance. To date, multiple audiometric, demographic, and surgical variables have shown some degree of correlation with CI speech perception outcomes. In the present study, postsurgical acoustic and electric hearing thresholds that are routinely assessed in clinical practice were compared to CI speech perception outcomes in order to reveal possible markers of postoperative cochlear health.

View Article and Find Full Text PDF

Introduction: Semicircular canal dehiscence (SCD) is defined as a defect of the bone overlying the semicircular canal. It has a relatively high prevalence of 3% in the general population, which makes it likely that a certain number of patients receiving a cochlear implant (CI) would have it. However, little is known about the influence of SCD on the CI outcome.

View Article and Find Full Text PDF

Objectives: (1) To correlate simultaneously recorded intra- and extracochlear electrocochleography (ECochG) signals during electrode insertion into the cochlea, (2) to track changes in the ECochG signal during insertion and removal of an electrode, and (3) to correlate the findings with the preoperative residual hearing. We hypothesized that intracochlear ECochG recordings show signal changes not reflected in simultaneous extracochlear ECochG recordings.

Design: During cochlear implantation in human cochlear implant recipients, a short, slim, custom-made electrode was inserted and removed in a stepwise manner.

View Article and Find Full Text PDF

The sheep middle ear has been used in training to prepare physicians to perform surgeries and to test new ways of surgical access. This study aimed to (1) collect anatomical data and inertial properties of the sheep middle-ear ossicles and (2) explore effects of these features on sound transmission, in comparison to those of the human. Characteristic dimensions and inertial properties of the middle-ear ossicles of White-Alpine sheep (n = 11) were measured from high-resolution micro-CT data, and were assessed in comparison with the corresponding values of the human middle ear.

View Article and Find Full Text PDF

In order to better understand bone conduction sound propagation across the skull, three-dimensional (3D) wave propagation on the skull surface was studied, along with its dependence on stimulation direction and location of a bone conduction hearing aid (BCHA) actuator. Experiments were conducted on five Thiel embalmed whole head cadaver specimens. Stimulation, in the 0.

View Article and Find Full Text PDF

Objective: To determine the correlation between intraoperative changes of electrocochleography (ECochG) responses and traumatic cochlear implant insertions as well as postoperative hearing loss.

Methods: ECochG, radiological, and audiological data were collected prospectively in a cochlear implant recipient with otosclerosis and assumed cochlear trauma during electrode insertion. A systematic review was conducted within PubMed-NCBI, EMBASE, and the Cochrane Library using the terms "Cochlear implant" and "Electrocochleography.

View Article and Find Full Text PDF