High-quality prostate magnetic resonance imaging (MRI) is required for accurate prostate cancer detection, localization, and staging. Variability in image quality exists in practice, influenced by inconsistent adherence to technical standards, lack of patient preparation, variability in scanner performance, patient characteristics, and knowledge gaps in personnel scheduling and performing prostate MRI exams. The Prostate Imaging Quality (PI-QUAL) scoring system is a well-established tool for assessing the diagnostic quality of prostate MRI.
View Article and Find Full Text PDFRadiol Imaging Cancer
March 2024
Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.
View Article and Find Full Text PDFInt J Hyperthermia
October 2023
Histotripsy is an emerging noninvasive, non-thermal, and non-ionizing focused ultrasound (US) therapy that can be used to destroy targeted tissue. Histotripsy has evolved from early laboratory prototypes to clinical systems which have been comprehensively evaluated in the preclinical environment to ensure safe translation to human use. This review summarizes the observations and results from preclinical histotripsy studies in the liver, kidney, and pancreas.
View Article and Find Full Text PDFPurpose: To determine the risk of mechanical vessel wall damage resulting in hemorrhage during and after hepatic and renal histotripsy in an anticoagulated in vivo porcine model.
Materials And Methods: Non-tumor-bearing pigs (n = 8; mean weight, 52.5 kg) were anticoagulated with warfarin (initial dose, 0.
Purpose: This study was designed to evaluate the feasibility and safety of histotripsy subcutaneous (SQ) fat treatment in an in-vivo porcine model, and evaluate evolution of the treated volume on MRI and pathology.
Methods/materials: 10 histotripsy SQ fat treatments were completed in 5 swine, divided into four groups based on pre-determined survival: day 0 (n = 4), day 7 (n = 2), day 28 (n = 2), and day 56 (n = 2). A 4.
Objective: To compare the acute and chronic safety and treatment effects of non-invasive hepatic histotripsy vs. percutaneous microwave (MW) ablation in a healthy porcine model.
Methods: This was a dual-arm study in which each animal (n = 14) received either a single hepatic microwave (n = 6) or histotripsy (n = 6 single treatment; n = 2 double treatment) under ultrasound guidance.
Purpose: To evaluate the efficacy and safety of microwave (MW) ablation as first-line locoregional therapy (LRT) for bridging patients with hepatocellular carcinoma (HCC) to liver transplant.
Materials And Methods: This retrospective study evaluated 88 patients who received percutaneous MW ablation for 141 tumors as first-line LRT for HCC and who were listed for liver transplantation at a single medical center between 2011 and 2019. The overall survival (OS) rate statuses after liver transplant, waitlist retention, and disease progression were evaluated using the Kaplan-Meier techniques.
J Gastrointest Oncol
August 2021
Background: The purpose of this study is to evaluate the safety and intermediate-term efficacy of percutaneous microwave (MW) ablation for the treatment of colorectal liver metastases (CRLM) at a single institution.
Methods: A retrospective review was performed of all CRLM treated with MW ablation from 3/2011 to 7/2020 (102 tumors; 72 procedures; 57 patients). Mean age was 60 years (range, 36-88) and mean tumor size was 1.
Cardiovasc Intervent Radiol
October 2021
Purpose: To evaluate the outcomes of computed tomography (CT) fluoroscopy-guided core lung biopsies with emphasis on diagnostic yield, complications, and efficacy of parenchymal and pleural blood patching to avoid chest tube placement.
Methods: This is a single-center retrospective analysis of CT fluoroscopy-guided percutaneous core lung biopsies between 2006 and 2020. Parenchymal blood patching during introducer needle withdrawal was performed in 74% of cases as a preventive measure, and pleural blood patching was the primary salvage maneuver for symptomatic or growing pneumothorax in 60 of 83 (72.
Int J Hyperthermia
July 2021
Introduction: This study was performed to determine the feasibility and safety of creating superficial histotripsy treatment in a live porcine thyroid model.
Methods: The porcine thymus comparable in size, shape and location to the human thyroid was used for this study. This model has been used for thyroid surgery studies due to the diminutive size of the porcine thyroid.
J Vasc Interv Radiol
March 2021
Purpose: To determine physician radiation exposure when using partial-angle computed tomography (CT) fluoroscopy (PACT) vs conventional full-rotation CT and whether there is an optimal tube/detector position at which physician dose is minimized.
Materials And Methods: Physician radiation dose (entrance air kerma) was measured for full-rotation CT (360°) and PACT (240°) at all tube/detector positions using a human-mimicking phantom placed in a 64-channel multidetector CT. Parameters included 120 kV, 20- and 40-mm collimation, and 100 mA.
The goal of this study was to compare intra-procedural radiofrequency (RF) and microwave ablation appearance on non-contrast CT (NCCT) and ultrasound to the zone of pathologic necrosis. Twenty-one 5-min ablations were performed in swine liver with (1) microwave at 140 W, (2) microwave at 70 W, or (3) RF at 200 W ( = 7 each). CT and US images were obtained simultaneously at 1, 3, and 5 min during ablation and 2, 5, and 10 min post-ablation.
View Article and Find Full Text PDFPurpose: Evaluate the safety and efficacy of adrenal microwave ablation performed with continuous intra-arterial blood pressure monitoring (IABPM) and without alpha-adrenergic blockade (AAB) as pretreatment.
Material And Methods: A single-center, retrospective review of all percutaneous adrenal microwave ablation performed between 2011 and 2018. Microwave ablation was completed on 11 patients, with a total of 15 adrenal tumors with a mean size of 3.
J Vasc Interv Radiol
August 2019
Purpose: To demonstrate the feasibility of Robotically Assisted Sonic Therapy (RAST)-a noninvasive and nonthermal focused ultrasound therapy based on histotripsy-for renal ablation in a live porcine model.
Materials And Methods: RAST ablations (n = 11) were performed in 7 female swine: 3 evaluated at 1 week (acute) and 4 evaluated at 4 weeks (chronic). Treatment groups were acute bilateral (3 swine, 6 ablations with immediate computed tomography [CT] and sacrifice); chronic single kidney (3 swine, 3 ablations; CT at day 0, week 1, and week 4 after treatment, followed by sacrifice); and chronic bilateral (1 swine, 2 ablations).
Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury.
View Article and Find Full Text PDFThe risk of electromagnetic interference between microwave (MW) ablation and cardiac implantable electronic devices (CIEDs), ie, pacemakers and defibrillators, has not been fully evaluated. Fourteen MW ablations (kidney, n = 8; liver, n = 5; lung, n = 1) were performed in 13 patients with CIEDs in normal operating mode. Electrocardiography tracings, cardiovascular complications, tumor size, tumor-to-CIED distance, and tumor-to-device lead distance were recorded.
View Article and Find Full Text PDF