At present, the redundant structures are one of the most effective methods for solving magnetic levitation bearing coil failure. Coil failure causes residual effective magnetic poles to form different support structures and even asymmetrical structures. For the magnetic bearing with redundant structures, how to construct the electromagnetic force (EMF) that occurs under different support structures to achieve support reconstruction is the key to realizing fault tolerance control.
View Article and Find Full Text PDFSensors (Basel)
April 2022
At present, magnetic bearings are a better energy-saving choice than mechanical bearings in industrial applications. However, there are strongly coupled characteristics in magnetic bearing-rotor systems with redundant structures, and uncertain disturbances in the electrical system as well as external disturbances, and these unfavorable factors degrade the performance of the system. To improve the anti-interference performance of magnetic bearing systems, this paper proposes the inverse of the current distribution matrix meaning that the active disturbance rejection control simulation model can be carried out without neglecting the current of each coil.
View Article and Find Full Text PDFFault tolerance is one of the effective methods to improve the reliability of magnetic bearings, and the redundant magnetic bearing provides a feasible measure for fault-tolerant control. The linearization and accuracy of the electromagnetic force (EMF) from the redundant structures is crucial for designing fault-tolerant controllers. In the magnetic bearing with a redundant structure, the current distribution matrix is an important factor that affects the accuracy of EMF.
View Article and Find Full Text PDF