Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Real-time polymerase chain reaction (PCR) is the gold standard for DNA detection in many fields, including food analysis. However, robust detection using a real-time PCR for low-content DNA samples remains challenging. In this study, we developed a robust real-time PCR method for low-content DNA using genetically modified (GM) maize at concentrations near the limit of detection (LOD) as a model. We evaluated the LOD of real-time PCR targeting two common GM maize sequences (P35S and TNOS) using GM maize event MON863 containing a copy of P35S and TNOS. The interlaboratory study revealed that the LOD differed among laboratories partly because DNA input amounts were variable depending on measurements of DNA concentrations. To minimize this variability for low-content DNA samples, we developed ΔΔCq-based real-time PCR. In this study, ΔCq and ΔΔCq are as follows: ΔCq = Cq (P35S or TNOS) - Cq (SSIIb; maize endogenous gene), ΔΔCq = ΔCq (analytical sample) - ΔCq (control sample at concentrations near the LOD). The presence of GM maize was determined based on ΔΔCq values. In addition, we used optimized standard plasmids containing SSIIb, P35S, and TNOS with ΔCq equal to the MON863 genomic DNA (gDNA) at concentrations near the LOD as a control sample. A validation study indicated that at least 0.2% MON863 gDNA could be robustly detected. Using several GM maize certified reference materials, we have demonstrated that this method was practical for detecting low-content GM crops and thus for validating GM food labeling. With appropriate standards, this method would be applicable in many fields, not just food.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583069 | PMC |
http://dx.doi.org/10.1021/acs.analchem.2c03680 | DOI Listing |